6/130
Siemens IK PI · 2015
■
Technical specifications (continued)
Industrial Wireless Communication
IWLAN – Accessories
IWLAN antennas
Article No. 6GK5792-8DN00-0AA6 6GK5793-8DJ00-0AA0 6GK5793-8DK00-0AA0 6GK5793-8DP00-0AA0
Product-type designation Antenna ANT792-8DN Antenna ANT793-6DJ Antenna ANT793-6DK Antenna ANT793-8DP
Wireless frequencies
Radio frequency
•for WLAN
in 2.4 GHz frequency band
2.4 … 2.7 GHz - - -
•for WLAN
in 5 GHz frequency band 1
- 5.25 … 5.875 GHz 5.15 … 5.875 GHz 4.9 … 5.35 GHz
•for WLAN
in 5 GHz frequency band 2
- - - -
Electrical data
Impedance 50 50 50 50
Polarization
linear vertical dual linear vertical-horizontal dual linear vertical-horizontal linear vertical
Radiation characteristic directional directional directional directional
Antenna gain compared to spherical
radiator with linear radiation
- - - -
Antenna gain compared to spherical
radiator with circular radiation
- - - -
Antenna gain compared to spherical
radiator of the WLAN antenna in the
2.4 GHz frequency band
14 dB - - -
Antenna gain compared to spherical
radiator of the WLAN antenna in the
5 GHz frequency band
- 18 dB 23 dB 13.5 dB
Standing wave ratio VSWR maximum
1.5 1.7 1.7 1.5
Beam angle of antenna
• in the 2.4 GHz frequency band
- horizontal 35° - - -
- vertical
30° - - -
• in the 5 GHz frequency band
- horizontal - 17° 9° 40°
- vertical
- 17° 9° 35°
Opening angle Note
- - - -
Number of electrical connections of
antenna
1 2 2 1
Design of electrical connection of
antenna
N connector N connector N connector N connector
Angle of inclination downward
maximum
0° 0° 0° 0°
Crosstalk attenuation between the
antenna connections
- 30 dB 40 dB -
Front-to-back ratio
20 dB 30 dB 35 dB 20 dB
Transmit power
• maximum 75 W 6W 6W 10 W
•Note
at 25° ambient temperature at 25° ambient temperature at 25° ambient temperature at 25° ambient temperature
Range with clear line of sight without
disturbance
1 000 m - - -
Range Note
Note:
The range can be consider-
ably less, depending on
spatial factors, the wireless
standard used, the data rate,
and the antennas at the other
end
- - -
Permitted ambient conditions
Ambient temperature
• during operating -40 … +80 °C -45 … +70 °C -45 … +70 °C -40 … +80 °C
• during storage
-40 … +80 °C -45 … +70 °C -45 … +70 °C -40 … +80 °C
• during transport
-40 … +80 °C -45 … +70 °C -45 … +70 °C -40 … +80 °C
• during installation
- - - -
Protection class IP
IP23 IP67 IP67 IP67
Wind load maximum
57 N 104 N 389 N 15 N
Wind load Note at 160 km/h frontal at 220 km/h frontal at 220 km/h frontal at 160 km/h