6/23
Siemens IK PI · 2015
Industrial Wireless Communication
IWLAN – Access Points IEEE 802.11n
SCALANCE W788 M12 for indoor use
■
Overview
• Particularly suitable for industrial applications without
control cabinets
■
Design
• Rugged aluminum enclosure, shock and vibration-proof,
for high mechanical requirements
• High IP65 degree of protection against dust and water jets
• For use at ambient temperatures from -20 °C to +60 °C
• 3 x N-Connect sockets for the connection of directly
mountable and remote antennas (6 x N-Connect sockets for
the variants with two wireless modules)
• Antenna placement optimized for the 3x3 MIMO technology;
the antennas do not interfere with each other when they are
mounted directly on the device
• Suitable for 2.4 GHz and 5 GHz
• 1 x M12 connection for 10/100/1 000 Mbit/s with Power-over-
Ethernet according to IEEE 802.3at
• 1 x M12 socket for power supply (24 V DC)
• 1 x PLUG compartment (KEY-PLUG/C-PLUG)
• Function LEDs for optical signaling of faults/errors and
operating statuses
• Mounting: Wall, S7-1500 mounting rail, S7-300 mounting rail,
or on 35 mm standard mounting rail
Design and interfaces of the SCALANCE W788-2 M12 access points
Product versions
SCALANCE W788-1 M12
• A radio card is permanently installed; functional scope can be
expanded by using a KEY-PLUG W780 iFeatures
SCALANCE W788-2 M12
• Two radio cards are permanently installed; functional scope
can be expanded by using a KEY-PLUG W780 iFeatures
3x N-Connect (female) connections for antennas
3x N-Connect
(female)
connections
for antennas
PLUG slot
24 V DC
connection
M12 connection
(Gigabit)
nprXWZWY][
Kap_06_IWC_en.book Seite 23 Dienstag, 7. Oktober 2014 1:47 13