Industrial Wireless Communication
IWLAN – Access Points IEEE 802.11n
SCALANCE W788 M12 for indoor use
6
Technical specifications
Article No. 6GK5788-1GD00-0AA0 6GK5788-2GD00-0AA0
6GK5788-1GD00-0AB0
1)
6GK5788-2GD00-0AB0
1)
Product-type designation SCALANCE W788-1 M12 SCALANCE W788-2 M12
Transmission rate
Transmission rate
• with W-LAN maximum 450 Mbit/s 450 Mbit/s
• with Industrial Ethernet
10 … 1 000 Mbit/s 10 … 1 000 Mbit/s
• note
- -
Interfaces
Number of electrical connections
• for network components
and terminal equipment
1 1
• for power supply
1 1
for redundant power supply
1 1
Design of electrical connection
• for network components
and terminal equipment
M12 interface (8-pole, A-coded) M12 interface (8-pole, A-coded)
• for power supply
M12 interface (4-pole, A-coded) M12 interface (4-pole, A-coded)
Number of optical interfaces
for optical waveguide at 100 Mbit/s
- -
Design of optical interface
for optical waveguide at 100 Mbit/s
- -
design of the removable storage
C-PLUG
Yes Yes
Interfaces wireless
Number of radio cards permanently
installed
1 2
Number of internal antennas
- -
Number of electrical connections
for external antenna(s)
3 6
Design of the electrical connection
for external antenna(s)
N-Connect (socket) N-Connect (socket)
Product property external antenna
can be mounted directly on device
Yes Yes
Supply voltage,
current consumption, power loss
Type of supply voltage DC DC
Supply voltage
• 1 from M12 Power Connector
(A-coded) for redundant power
supply
19.2 V 19.2 V
• 2 from M12 Power Connector
(A-coded) for redundant power
supply
28.8 V 28.8 V
• from Power-over-Ethernet
according IEEE802.3at for type 1
and IEEE802.3af
48 V 48 V
• from Power-over-Ethernet
according IEEE802.3at for type 2
50 V 50 V
Current consumed
at 24 V with DC typical 0.45 A 0.63 A
• with Power-over-Ethernet
according to IEEE802.3at for type 1
and IEEE802.3af typical
0.22 A 0.22 A
• with Power-over-Ethernet
according to IEEE802.3at
for type 2 typical
- 0.3 A
Effective power loss
at 24V for DC typical 10.7 W 15 W
• with Power-over-Ethernet
according to IEEE802.3at
for type 1 and IEEE802.3af typical
- 10.7 W
• with Power-over-Ethernet
according to IEEE802.3at
for type 2 typical
- 15 W