Industrial Wireless Communication
IWLAN – Accessories
IWLAN antennas
6
Technical specifications
Article No. 6GK5795-4MC00-0AA3 6GK5795-4MD00-0AA3 6GK5795-4MA00-0AA3
Product-type designation Antenna ANT795-4MC Antenna ANT795-4MD Antenna ANT795-4MA
Wireless frequencies
Radio frequency
•for WLAN
in 2.4 GHz frequency band
2.4 … 2.4835 GHz 2.4 … 2.4835 GHz 2.4 … 2.4835 GHz
•for WLAN
in 5 GHz frequency band 1
5.15 … 5.35 GHz 5.15 … 5.35 GHz 5.15 … 5.35 GHz
•for WLAN
in 5 GHz frequency band 2
5.725 … 5.85 GHz 5.725 … 5.85 GHz 5.725 … 5.85 GHz
Electrical data
Impedance 50 50 50
Polarization linear vertical linear vertical linear vertical
Radiation characteristic
omnidirectional omnidirectional omnidirectional
Antenna gain compared to spherical
radiator with linear radiation
- - -
Antenna gain compared to spherical
radiator with circular radiation
- - -
Antenna gain compared to spherical
radiator of the WLAN antenna in the
2.4 GHz frequency band
3dB 3dB 3dB
Antenna gain compared to spherical
radiator of the WLAN antenna in the
5 GHz frequency band
5dB 5dB 5dB
Standing wave ratio VSWR maximum
2 2 2
Beam angle of antenna
in the 2.4 GHz frequency band
- horizontal 36 360° 360°
- vertical
- - -
• in the 5 GHz frequency band
- horizontal 36 360° 360°
- vertical
- - -
Opening angle Note - - -
Number of electrical connections of
antenna
1 1 1
Design of electrical connection of
antenna
N connector N connector R-SMA connector
Angle of inclination downward
maximum
Crosstalk attenuation between the
antenna connections
- - -
Front-to-back ratio
- - -
Transmit power maximum
- - -
Transmit power Note
- - -
Range with clear line of sight without
disturbance
- - -
Range Note
- - -
Permitted ambient conditions
Ambient temperature
during operating -20 … +65 °C -20…+6C -20 … +65 °C
during storage
-20 … +65 °C -20…+6C -20 … +65 °C
during transport
-20 … +65 °C -20…+6C -20 … +65 °C
during installation
- - -
Protection class IP
IP65 IP65 IP30
Wind load maximum
- - -
Wind load Note - - -
Kap_06_IWC_en.book Seite 125 Dienstag, 7. Oktober 2014 1:47 13
© Siemens AG 2014
Vista de página 124