FB FIELD_PAIR_SWITCHING (FB4, DB4)
The following table describes the parameters.
Parameter Explanation
SEN_FIELD1 Position switch 1 (NC)
SEN_FIELD2 Position switch 2 (NC)
SEN_FIELD3 Memory bit as dummy
SEN_FIELD4 Memory bit as dummy
FIELD_BIT0
FIELD_BIT1
FIELD_BIT2
Number of the detection zone
(Bit 0, bit 1 and bit 2 of the cyclic output data)
A maximum of four zone pairs can be activated. However, only one zone
pair can be active at any time. In the safety functional example, either zone
pair 1 or zone pair 2 can be active. It is possible to switch from zone pair 1
to 2 and from zone pair 2 to 1. It depends on the cyclic output data (bit 0, bit
1, bit 2) which zone pair is active.
The following assignments apply:
FIELD_BIT2 FIELD_BIT1 FIELD_BIT0 Active
zone pair
Note
0 0 1 1
0 1 0 2
Implemented in the
safety functional example
0 1 1 3
1 0 0 4
Prepared in the safety
functional example
The states of these three bits are determined by the status of the position
switches (SEN_FIELD1, SEN_FIELD2).
Note
During zone pair switching, the PC adapter must not be connected. The
PC adapter must not be plugged in at the SIMATIC FS600.