The following table describes the parameters.
Parameter Explanation
SEN_FIELD1 Position switch 1 (NC)
“1“ signal: Switch not applied.
SEN_FIELD2 Position switch 2 (NC)
“1“ signal: Switch not applied.
SEN_FIELD3 Memory bit as dummy
SEN_FIELD4 Memory bit as dummy
FIELD_BIT0
FIELD_BIT1
FIELD_BIT2
Number of the detection zone
(Bit 0, 1 and 2 of the cyclic output data)
Network 3
Here the FC REINTEGRATION (FC3) is called. FC3 is described further
below.
FB SET_ACT (FB3, DB3)
Network 1
The status of the SR flip-flop (#EN) is evaluated in OB1 as a condition for a
start.
In case of a detection zone violation, OSSD becomes “0“ and resets the SR
flip-flop (reset has the priority with this flip-flop bit). As a result, #RELEASE
(used in network 2) takes on the value “0”.
Network 2
The actuator (indicator light) is only switched on if both conditions are
satisfied.
start condition fulfilled (COND1=”1”, see OB1)
release was given (RELEASE=”1”, see previous network 1)