Siemens SIMATIC FS600 Instruções de Operação Página 26

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 51
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 25
Distributed Use of SIMATIC FS600 Laser Scanner in
Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 26/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
Testing inputs and outputs
Prerequisites:
The inputs and outputs have the default values specified under
“Inputs/outputs used”.
No objects are currently in the detection zone of the
laser scanner SIMATIC FS600.
ResponseNo. Action
A 8.0
Note
1
Hold position switch 1
on “0” signal
“0“
2
Hold position switch 2
on “1” signal
“0“
Activating zone pair 1
(detection zone 1 and warning zone 1)
3
Press the push button ACK
and release it
“0“
Acknowledgement necessary at initial
start.
4
Press the START push button
and release it
“1“ Start of the “machine”
5
Press the STOP push button
and release it
“0“ Stop of the “machine”
6
Press the START push button
and release it
“1“ No acknowledgement required for start
7
Place an object into the
detection zone of the laser scanner
SIMATIC FS600.
“0“ Violation of the detection zone
8
Remove the object from the
detection zone of the laser scanner
SIMATIC FS600.
“0“ ---
9
Press the START push button
and release it
“0“
Acknowledgement necessary prior to
the start.
10
Press the push button ACK
and release it
“0“ Acknowledgement
11
Press the START push button
and release it
“1“ The “machine” can be started again.
Vista de página 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 50 51

Comentários a estes Manuais

Sem comentários