Distributed Use of SIMATIC FS600 Laser
Scanner in Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 13/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
Explanation of the above times
Time Note / Explanation
t1 Switching the actuator on: Indicator light goes on (ACTUATOR=“1“).
t2 Switching the actuator off: Indicator light goes on (ACTUATOR=“0“).
t3 Switching the actuator on: Indicator light goes on (ACTUATOR=“1“).
t4
The laser scanner SIMATIC FS600 recognizes a violation of the active
detection zone (OSSD=“0“)
t5
A new start request does not cause the indicator light to be switched on. It
hast to be acknowledged first (see below).
t6 Acknowledgement
t7 The start request now causes the actuator (indicator light) to be switched on.
Reaction times
Use the Excel file available for S7 Distributed Safety V 5.4 to calculate the
max. response time of your F system. This file is available on the internet:
http://support.automation.siemens.com/WW/view/en/25412441
2.2 Advantage / Customer benefits
SIMATIC Safety Integrated
Wiring reduced to a minimum due to use of fail-safe S7-CPU and
distributed I/O. The more safety functions are implemented, the more
useful this advantage is.
Programming the fail-safe program with STEP7 engineering tools.
Only one S7-CPU is required, since fail-safe program parts run on a
coexistent basis in the S7-CPU
Use of prefabricated and certified failsafe blocks from the S7 Distributed
Safety library (F application blocks).
Laser scanner SIMATIC FS600
Four fully configurable detection zone pairs
Detection zone switching with any sensors
without additional evaluation device
Monitored radius up to 190°
Low current draw (approx. 300 mA)
Simple connection to PROFIBUS-DP
Comfortable configuration and diagnostics software LS4soft