Distributed Use of SIMATIC FS600 Laser Scanner in
Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 21/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
The laser scanner SIMATIC FS600 has five male/female connectors
(X1 to X5).
Connect these male/female connectors as follows:
Male/female
connector
Function Note / Explanation
X1
Restart
button
Connect a push button (NO) here. (This is considered in chapter 3
in the “Hardware components” table.)
The push button has two functions:
• Unlocking the internal start or restart inhibit of the laser
scanner SIMATIC FS600, if activated. This function is not
activated in the safety functional example. But a restart inhibit
is implemented in the safety program.
• Error acknowledgement, if the laser scanner SIMATIC FS600
is in failure mode.
X2
PROFIBUS
output
If the laser scanner SIMATIC FS600 is the last device on the
PROFIBUS, a standards compliant terminating resistor must be
connected.
X3
PROFIBUS
input
---
X4
Power
supply
Pin 1: +24V DC
Pin 3: 0V DC
X5
Optical PC
interface
(also
referred to
as PC
adapter)
Connected to the COM interface of the PG/PC on which the
LS4soft configuration and diagnostics software has been installed.