Fragmentation errors
Sum of all failed fragmentations. One of the fragments was not received or
received too late.
Encryption errors
Is incremented if a frame is received in which the WEP bit is set and the device
operates without encryption, or the reverse situation when a packet is received
without a WEP bit and encryption is enabled.
Duplicate frames
Sum of all frames received twice.
FCS errors
Sum of all packets received in which the checksum was incorrect.
Header CRC error
Sum of all packets received in which the header checksum was incorrect.
Decrypt CRC error
Sum of all packets received in which the checksum of the encrypted data buffer
was incorrect.
Transmit Errors
Transmission errors
Is incremented when a frame cannot be sent successfully despite hardware
retries.
Dropped frames
Number of packages that were dropped either when the packet was not sent
despite all retries or packets that had not been sent when a node deregistered.
Acknowledged errors
Sum of all packets sent that were not confirmed by an acknowledge.
RTS errors
Sum of all sent RTS frames that were not acknowledged by a CTS.
Retry count
Sum of all frames sent successfully that required one or more retries.
One retry count
Sum of all frames sent successfully that required exactly one retry.
Multiple retry count
Sum of all frames sent successfully that required more than one retry.
Note
The percentages shown following the errors relate to the entire received/sent
frames.