Configuration Using Web Based Management and the Command Line Interface
6.6 The Filters Menu
C79000-G8976-C184-07
210
commands are available only
available when you operate the SCALANCE W78x in the access point mode. You
can specify the mode in the System menu.
Note
The Filter menu and the corresponding menu
6.6.1 MA
nied for all
specified MAC addresses. You can enter a maximum of 50 MAC addresses in the
ble.
.
e
C Filter Menu Command
If the MAC filter is activated, communication with clients on the Ethernet side is
possible only when their source MAC addresses are entered in the table. As an
alternative, it is possible to make a setting in which access is de
ta
With IP mapping of a SCALANCE W78x in client mode, only the MAC address
assigned to this device is relevant, the MAC addresses of the devices downstream
from it on the Ethernet side are irrelevant for filtering
Syntax of the Command Line Interfac
CLI\BRIDG
Command Description Comment
E\ MAC1FLT>
fltmac1 <E|D>
Enables / disables the filter.
statmac1 [F|B]
If the value is set to F (forwarding),
only packets with a source address
contained in the table are forwarded.
In mode B (blocking), these packets
are blocked and all others are
forwarded.
add <MAC addr.>
[description]
Adds a new address to the filter list.
The optional description has no
influence on the list and simply
serves as information for the user.
edit <Number|MAC> [E|D]
[Description]
Changes the specified value.
delete <Number|MAC>
Deletes the entry from the list.
clearall
Deletes all entries from the list.