Configuration Using Web Based Management and the Command Line Interface
Note
C79000-G8976-C184-07
133
As of firmware version V3.0, the file with the configuration data of the AP also
includes the following information
Version of the configuration file
Configuration files generated with a device with firmware version V2.4 or older, can
e loaded on devices with firmware version V3.0 without causing problems.
uration files generated with a device with firmware version V3.0, cannot,
version V2.4 or older.
Firmware version with which this configuration file was created
Order number (MLFB) of the device with which the configuration file was
created
It is necessary that the configuration on the C-PLUG was generated with a
firmware version the firmware version on the destination device.
Example:
b
Config
however, be loaded on devices with firmware
Reusing Configuration Data
ata reduces the effort if several SCALANCE
W78x devices have the same configuration and when IP addresses are obtained
figuration data on a PC after you have configured a
load this file to all other SCALANCE W78x devices you
How to Lo r HTTP / HTTPS
data
.
lternative, you can also use a file selection dialog that opens after you
click the Browse... button.
clicking the Save button. Start the load from file
ction by clicking the Load button.
How to Load or Save Data over TFTP
1 Enter the IP address of the TFTP server in the TFTP Server IP text box.
2. Enter the port of the TFTP server in the Port text box in the default value does
not meet your requirements.
3. Click on the Set Values button before you enter any further information for
saving the data.
Saving and reading in configuration d
over DHCP. Save the con
SCALANCE W78x. Down
want to configure. If necessary, you may need to assign an IP address to this
SCALANCE W78x first using the Primary Setup Tool.
ad or Save Data ove
1. Specify the name of the file from which the data will be taken or where the
will be saved in the relevant text box for the configuration data or firmware
As an a
2 Start the save function by
fun
Operating Instructions SCALANCE W78x