Modify C-PLUG list box, Modify button
ou are logged on as administrator.
nal Configuration to C-PLUG
The configuration in the internal flash memory of the switch is copied to
the C-PLUG; this is followed by a restart.
There is one important use case for this function: The device has started
up with a C-PLUG containing a bad configuration or a configuration
different from the device. If you have not yet made any configuration
changes after starting up the device, you can use this function to
overwrite the content of the C-PLUG with the original device
configuration.
● Load default Configuration to C-PLUG and Restart
A configuration with all the factory default values is stored on the C-
PLUG. This is followed by a restart in which the SCALANCE W78x starts
up with these default values.
● Clean C-PLUG (Low Level Format, Configuration lost)
Deletes all data on the C-PLUG and starts a low-level formatting function.
There is no automatic restart.
● Create PRESET PLUG
Writes configuration data to a PRESET PLUG. For detailed information
on this topic, refer to Section 3.4
After making your selection, start the function by clicking the Modify button.
You can only make settings in this box if y
Here, you decide how you want to change the content of the C-PLUG. The
following alternatives are possible: