Configuration Using Web Based Management and the Command Line Interface
C79000-G8976-C184-07
213
res menu and the co s are available only
n you ope ce point mode. You can
specify the mode in the
6.7 The I-Features Menu
Note
The I-Featu rr enu command
rate the SCALANCE W78x in ac
System menu.
esponding m
available whe ss
6 omman
This function is not ava
.7.1 iQoS Menu C d
Note
ilable in iPCF mode.
Client-Specific Bandwidth Reserv
iQoS (Quality of Servic ts are assigned a certain
bandwidth. Due to this robability that data
transmission to these clients will be within a defined period. This technique can be
useful when response times must be guaranteed. If non-iQoS-clients put too much
load on the network, they can be logged off from the AP to guarantee data traffic
for iQoS clients.
Note
To ensure problem-free functioning of the iQoS mode, the number of clients with
bandwidth reservation is restricted to four.
ation
e) is technique with which clien
assignment, there is a high p
Note
If the user reserves data for critical clients, this data rate also includes the frame
header (in other words, 802.11, MAC, IP, TCP, and S7 header). A SIMATIC user
must therefore take into account not only the net data during configuration but also
the headers.
Response Time
In the Response Time text box, you enter the required response time of the
SCALANCE W78x over the wireless interface. Remember that this value
represents the transmission time for the data from the SCALANCE W78x to the
client. The data transmission rate for nodes not included in the list is reduced
according the values specified.