Absolute
ECI 1319 EQI 1331
Interface
EnDat 2.2
Ordering designation EnDat22
Position values/revolution 524 288 (19 bits)
Revolutions 4 096 (12 bits)
Elec. permissible speed/
deviations
1)
i15 000 min
–1
(for continuous position value)
Calculation time t
cal
Clock frequency
i 5 μs
i 16 MHz
System accuracy
± 65”
Electrical connection via
PCB connector
Rotary encoder: 12-pin
Thermistor
1)
: 4-pin
Cable length i P
Voltage supply 3.6 V to 14 V DC
Power consumption
(maximum)
At 3.6 V: i 650 mW
At 14 V: i 700 mW
At 3.6 V: i 750 mW
At 14 V: i 850 mW
Current consumption
(typical)
At 5 V: 95 mA (without load) At 5 V: 115 mA (without load)
Shaft*
Blind hollow shaft for axial clamping 12.7 mm
Mech. permiss. speed n i 15 000 min
–1
i 12 000 min
–1
Moment of inertia of rotor 2.6 x 10
–6
kgm
2
Permissible axial motion of
measured shaft
± 0.5 mm
Vibration 55 to 2 000 Hz
2)
Shock 6 ms
Stator: i 400 m/s
2
; rotor: i 600 m/s
2
(EN 60 068-2-6)
i 2 000 m/s
2
(EN 60 068-2-27)
Max. operating temp.
115 °C
Min. operating temp.
–40 °C
Protection EN 60 529 IP 20 when mounted
Weight
Approx. 0.13 kg
1)
Evaluation optimized for KTY 84-130
2)
10 Hz to 55 Hz, constant over distance, 4.9 mm peak to peak
Functional safety available. For dimensions and specifi cations, see the Product Information document.
Antriebsgeber_en_2013.indd 69 12.11.2013 06:55:51