ECI/EQI 1100 series
Absolute rotary encoders
• Flange for axis mounting
• Blind hollow shaft
• Without integral bearing
$ = Bearing of mating shaft
N = Required mating dimensions
P = Measuring point for operating temperature
¢ = PCB connector, 15-pin
£ = Permissible surface pressure (material: aluminum 230 N/mm
2
)
¤ = Centering collar
¥ = Bearing surface
¦ = Clamping surfaces
§ = Self-locking screw M3 x 20, ISO 4762, width A/F 2.5, tightening torque: 1.2 ±0.1 Nm
¨ = Start of thread
© = Maximum permissible deviation between shaft and fl ange surfaces.
Compensation of mounting tolerances and thermal expansion, no dynamic motion permitted
ª = Direction of shaft rotation for output signals as per the interface description