EMCO WINNC SINUMERIK 810/820 T ALARMS / MESSAGES
H 3
2046 Block greater than 120 characters
Cause: NC block is too long (with loading a pro-
gram)
Remedy: divide NC block in several blocks with DOS
editor
2048 Nxxxx Circle end point error
Cause: invalid circle, invalid circle centre, radius
too small
Remedy: correct program
2060 Nxxxx Pogramming error TO, ZO
Cause: D number too great, tool type not allowed
Remedy: correct program
2061 Nxxxx General program error
Cause: NC block structure wrong, block number,
M/H/G code not allowed, invalid combina-
tion of G commands, radius/dwell program-
med twice, dwell time too long, circle already
programmed, general block structure error
with calculating operation
Remedy: correct program
2062 Nxxxx Feed missing / not progr.
Cause: F value too great, attempt to start with F=0,
also with G95/96, if S=0 or M5
Remedy: correct program
2063 Nxxxx Thread lead to high
Cause: thread pitch too great / missing, feed with
threads reaches 80% of rapid speed
Remedy: correct program, smaller pitch or lower
speed with threads
2065 Nxxxx Pos behind SW overtr. switch
Cause: target point programmed out of software
end switch or circle path overtravels
software end switch
Remedy: correct program
2068 Nxxxx Pos behind working area
Cause: target point programmed out of working area
Remedy: correct program
2072 Nxxxx Incorrect input value
Cause: chamfer/radius too large
Remedy: correct program
2073 Nxxxx No intersection point
Cause: no intersection point with contour definition
arc-line
Remedy: correct program
2074 Nxxxx Wrong angle value
Cause: no contour draft is possible with that angle
Remedy: correct program
2075 Nxxxx Incorrect radius value
Cause: wrong circle centre point or radius
Remedy: correct program
2076 Nxxxx Wrong G02/G03
Cause: wrong rotational direction for tangential
draft arc-line programmed
Remedy: correct program
2077 Nxxxx Incorrect block sequence
Cause: chamfer/radius: no 2. traverse block was
programmed
Remedy: correct program
2081 Nxxxx CRC not allowed
Cause: thread, change of correction direction/mirror
axis/tool correction not allowed with CRC,
circle not in selected CRC plane, change of
plane while CRC
Remedy: correct program
2082 Nxxxx CRC not determinable
Cause: plane change CRC not allowed, invalid
contour element, contour violation full circle,
contour element too short
Remedy: correct program
2160 Nxxxx Scale factor not allowed
2171 Nxxxx Approach not possible
Cause: no tool correction, tool radius = 0 (CRC)
Remedy: select tool, enter tool radius in tool data
2172 Nxxxx Retract not possible
Cause: error with selection CRC
Remedy: correct program
2501 ORDxx Synchronisation-error AC
Remedy: RESET, report to EMCO if repeatable
2502 ORDxx Synchronisation-error AC
Remedy: RESET, report to EMCO if repeatable
2503 ORDxx Synchronisation-error AC
Remedy: RESET, report to EMCO if repeatable
2504 ORDxx Insuff. RAM for interpreter
Cause: not enough RAM memory, continuation of
the program not possible
Remedy: close all other WINDOWS applications,
cease program, remove resident programs
(from AUTOEXEC.BAT and CON-
FIG.SYS), restart PC
2505 ORDxx Insuff. RAM for interpreter
see 2504
2506 ORDxx Insufficient RAM
see 2504
2507 ORDxx Referencepoint not active
Remedy: approach reference point
2508 ORDxx Intenal error NC core
Remedy: RESET, report to EMCO if repeatable