EMCO WINNC SINUMERIK 810/820 T ALARMS / MESSAGES
H 1
H: Alarms and Messages
Startup Alarms
These alarms can occur only with starting WinNC or
WinCTS.
0001 Error creating the file ...
Remedy: Check whether the directories exist, which
are entered in the .INI files.
Check whether writing access is possible
to these directories.
Check whether the disk is full.
0002 Error opening the file ...
Remedy: Check whether the directories exist, which
are entered in the .INI files.
Check whether reading access is possible
to these directories (number of simulta-
neous open files).
Copy the correct file in the corresponding
directory.
0003 Error reading the file ...
see 0002.
0004 Error writing the file ...
see 0001
0005 Too less RAM ...
Remedy: Close other WINDOWS applications
Restart WINDOWS
0006 Non compatible software version ...
Remedy: Software update.
0007 Invalid licence version ...
Remedy: Contact EMCO.
0011 Serial interface ... for digitizer is already
in use
Cause: The serial interface no. ... is already
occupied by another device.
Remedy: Remove the other device and connect the
digitizer or define another serial interface
for the digitizer.
0012 Serial interface ... for control keyboard is
already in use
analogous to 0011
0013 Invalid settings for serial interface ...
Cause: The actual settings of the serial interface
are not allowed for WinNC.
Allowed settings:
Baud rate: 110, 300, 600, 1200, 2400,
4800, 9600, 19200
Number of data bits: 7 or 8
Number of stop bits: 1 or 2
Parity: none, even or odd
Remedy: Change the settings of the serial interface
in the WINDOWS system control (connec-
tions).
0014 Serial interface ... not present
Remedy: Select an existing serial interface.
0015- 0023 (various alarms)
Remedy: Restart WINDOWS. If these alarm occur
repeatedly, contact EMCO.
0024 Invalid entry for control keyboard
interface in the profile ...
Cause: The connection of the control keyboard in
the file project.ini is invalid.
Remedy: Setting with WinConfig
0025 Invalid entry for digitizer interface in the
profile ...
analogous to 0024
0026 Invalid entry for notebook option in the
profile ...
Cause: The notebook entry in the file project.ini is
invalid.
Remedy: Setting with WinConfig
0027 Error creating the start window
Remedy: Restart WINDOWS. If this alarm occurs
repeatedly, contact EMCO.
0028 Invalid entry for window representation
in the profile ...
Cause: The presentation entry in the file project.ini
is invalid.
Remedy: Setting with WinConfig
0029 Error initializing a timer
Remedy: Close all other WINDOWS applications or
restart WINDOWS.
0030 Windows 3.1 or higher required
WinNC requires WINDOWS version 3.1 or higher.
0031 - 0036 (various alarms)
see 0002