EMCO WINNC SINUMERIK 810/820 T
C 10
OPERATING SEQUENCES
Program Interruption
1. Way
Change to the modes JOG or INC 1 ... INC 10 000.
With these changes no RESET occurs.
The drives will be stopped with holding the
programmed tool path.
Display: HALT: AUTO interrupted
2. Way
Press the key .
The drives will be stopped with holding the
programmed tool path.
Display: HALT: AUTO interrupted
Overstore
The function OVERSTORE changes one or several
values in the intermediate store.
For OVERSTORE the program has to be stopped.
• Press key .
• Extend softkey line (key
>
) and press softkey
OVERSTORE.
• Now you can enter new values for tool position T,
spindle speed S, auxiliary function H and
miscellaneous function M.
• Press the key , to activate the alterations and
continue the program.
• The program runs with these new values, until in
the program or by repeated OVERSTORE this
values will be altered.
Block Search
With this function you can start a program at any
block.
While block search the same calculations will be
proceeded as with normal program run but the slides
does not move.
• Press the key RESET ( ).
• Select the mode AUTOMATIC.
• Extend displayed softkey line (
>
) and press
softkey BLOCK SEARCH.
• Enter % for a main program resp. L for a subroutine
and press the key .
• Enter the program number via keyboard and
press the key .
• Enter the block number for the search target via
keyboard and press the key .
• Press the softkey START.
The program blocks will be worked off until the
given search target is reached.
• With the key you can activate the program
run.
Status Display of the PLC
Only on machines with PLC (Programmable Logical
Control) - e.g. PC TURN 50 with tool turret.
• Press softkey DIAGNOSIS
• Press softkey PLC- STATUS
The statii to be displays can be entered directly
e.g.: EB10,H
H hex
B binary
D decimal
The data format (H, B, D) need not to be determined.
If no format is determined the format is like shown in
the table.
Name Address area Remark Format
E 0 - 127 input byte B
A 0 - 127 output byte B
M 0 - 255 marker B
S 0 - 255 S-marker B
DB 0 - 255 data module D
DW 0 - 255 data word* H
Z 0 - 31 counter D
T 0 - 63 time D
*... before DW can be displayed, with DB a data
module has to be selected.
Display of the Software Versions
• Press softkey DIAGNOSIS
• Press softkey SW VERSION
The software version of the control system and the
eventually connected RS 485 devices will be
displayed.