EMCO WINNC SINUMERIK 810/820 T
C 10
OPERATING SEQUENCES
Program Interruption
1. Way
Change to the modes JOG or INC 1 ... INC 10 000.
With these changes no RESET occurs.
The drives will be stopped with holding the
programmed tool path.
Display: HALT: AUTO interrupted
2. Way
Press the key .
The drives will be stopped with holding the
programmed tool path.
Display: HALT: AUTO interrupted
Overstore
The function OVERSTORE changes one or several
values in the intermediate store.
For OVERSTORE the program has to be stopped.
Press key .
Extend softkey line (key
>
) and press softkey
OVERSTORE.
Now you can enter new values for tool position T,
spindle speed S, auxiliary function H and
miscellaneous function M.
Press the key , to activate the alterations and
continue the program.
The program runs with these new values, until in
the program or by repeated OVERSTORE this
values will be altered.
Block Search
With this function you can start a program at any
block.
While block search the same calculations will be
proceeded as with normal program run but the slides
does not move.
Press the key RESET ( ).
Select the mode AUTOMATIC.
Extend displayed softkey line (
>
) and press
softkey BLOCK SEARCH.
Enter % for a main program resp. L for a subroutine
and press the key .
Enter the program number via keyboard and
press the key .
Enter the block number for the search target via
keyboard and press the key .
Press the softkey START.
The program blocks will be worked off until the
given search target is reached.
With the key you can activate the program
run.
Status Display of the PLC
Only on machines with PLC (Programmable Logical
Control) - e.g. PC TURN 50 with tool turret.
Press softkey DIAGNOSIS
Press softkey PLC- STATUS
The statii to be displays can be entered directly
e.g.: EB10,H
H hex
B binary
D decimal
The data format (H, B, D) need not to be determined.
If no format is determined the format is like shown in
the table.
Name Address area Remark Format
E 0 - 127 input byte B
A 0 - 127 output byte B
M 0 - 255 marker B
S 0 - 255 S-marker B
DB 0 - 255 data module D
DW 0 - 255 data word* H
Z 0 - 31 counter D
T 0 - 63 time D
*... before DW can be displayed, with DB a data
module has to be selected.
Display of the Software Versions
Press softkey DIAGNOSIS
Press softkey SW VERSION
The software version of the control system and the
eventually connected RS 485 devices will be
displayed.