Configuration Using Web Based Management and the Command Line Interface
Operating Instructions SCALANCE W 744-1PRO
C79000-G8976-C185-03
57
Syntax of the Command Line Interface
CLI\SYSTEM\SNTP>
Command Description Comment
server [IP address]
Specifies the IP address of the
SNTP server.
tzone [hours]
Specifies the deviation of the time
zone of the SCALANCE W744 ac-
cording to UTC (Universal Time
Conversion) in hours.
5.2.9 Fault State Menu Command
This page displays information on faults/errors that have occurred. You can delete
this information if you click on the Remove Fault State button.
If you operate the SCALANCE W744 as an access point, texts (for example Link
with some safe-ip client(s) is/was broken ) are also displayed here for the IP Alive
and Link Check functions. After clicking on the text, the SCALANCE W744 displays
a list with the individual error messages. You acknowledge each error message by
clicking on it. Acknowledged messages are cleared from the list. You can acknowl-
edge all messages at once by clicking on the text Acknowledge all errors.
CLI\SYSTEM\FAULT>
Command Description Comment
fault [OFF]
Display the fault status and cause of
the fault.
You can reset the LED
and the fault status with
the command: "fault
OFF“. Ideally, however,
the cause of the problem
should be eliminated.
5.2.10 Load & Save Menu Command
Saving and Loading Device Data
Clicking the Load & Save menu command first opens a page with the current firm-
ware version. The HTTP and TFTP submenus allow you to save device data in ex-
ternal files or to transfer data from external files to the SCALANCE W744.