Configuration Using Web Based Management and the Command Line Interface
Operating Instructions SCALANCE W 744-1PRO
56 C79000-G8976-C185-03
CLI\SYSTEM\SNMP\USER>
Command Description Comment
add <user name>
<group name>
[NONE|MD5|SHA]
[authentication ID]
[Encryption ID]
Assigns an SNMPv3 user to a
group.
If authentication is necessary for the
group, the algorithm must be speci-
fied as a parameter (MD5 or SHA).
If authentication is necessary for the
group, the authentication password
must be specified
If encryption is necessary for the
group, the encryption password must
be specified as a parameter.
The authentication pass-
word and the encryption
password can be a maxi-
mum of 63 characters
long.
edit <Index>
<group name>
[NONE|MD5|SHA]
[authentication ID]
[Encryption ID]
Changes the group assignment, the
authentication algorithm, and the
encryption password of the SNMPv3
user.
delete <Index>
Deletes an SNMPv3 user from the
list at the point identified by the in-
dex.
clearall
Deletes all SNMPv3 users.
CLI\SYSTEM\SNMP\TRAP>
Command Description Comment
traps [E|D]
Enables / disables SNMP traps. Traps are then enabled, if
SNMP v1, v2c is also en-
abled.
settrap <entry>
<IP address>
<E|D>
Specifies the IP address of the trap
recipient entry (entry between 1 and
10) and enables / disables the send-
ing of traps to this recipient.
5.2.8 SNTP Config Menu Command
Time-of-Day for Synchronization in the Network
SNTP is the acronym for Simple Network Time Protocol. An SNTP server uses this
protocol to provide a uniform time throughout the entire network. Clients can syn-
chronize themselves with this time.
If you enter the IP address of an SNTP server here and select the time zone of the
SCALANCE W744, the SCALANCE W744 uses the time information from the
server. The SCALANCE W744 adopts this time information without any further
conversion regarding daylight-saving or standard time.