Configuration Using Web Based Management and the Command Line Interface
Operating Instructions SCALANCE W 744-1PRO
C79000-G8976-C185-03
45
Symbols for Representing CLI Commands
CLI commands generally have one or more parameters that are represented in the
syntax description as follows:
● Mandatory parameters are shown in pointed brackets.
Example: <IP address>
● Optional parameters are shown in square brackets.
Example: [E|D]
If you omit an optional parameter, most commands output the currently set va-
lue.
● Alternative input values are separated by the pipe character. In this case, you
specify one of the listed values as the parameter.
Example: [E|D]
You must enter either E or D.
● If a numeric value is required as a mandatory parameter, you can also specify a
range of values:
Example: <0 ... 255>
You must enter a value between 0 and 255.
Cross-menu Commands
You can use the commands in the following table in any menu.
CLI\ ... >
Command Description Comment
/
Moves you one menu level higher.
?
Displays the commands and submenus
available in the menu.
exit
Closes the CLI/TELNET session. Cannot be called us-
ing the command
shortcuts.
trace [Mod] [+|-][Level]
Enables / disables the trace function.
For troubleshooting
IQoS, errors, and
statistics
restart
Restarts the SCALANCE W744 Cannot be called us-
ing the command
shortcuts.
info
Displays information on the current me-
nu item.