Commissioning
Operating Instructions SCALANCE W 744-1PRO
C79000-G8976-C185-03
31
Press each individual hinge element to-
gether with the integrated IDC contact.
Recommendation: Use a small slotted
screwdriver (max. 3.5 mm) as a lever.
Push the housing over the assembled
data module and the insulator body until
they lock together (there should be an au-
dible click).
Tighten the cable gland. We recommend
an open ring key with a size of 21 mm.
3.3.4 Pinout of the M12 Connector
X2 Socket
PIN 1 24 V DC
PIN 2 --
PIN 3 Ground
PIN 4 --