Analog Modules
5-143
S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07
Technical Specifications of the SM 432; AO 8 x 13 Bit
Programming package
Associated programming
package
As of STEP 7 V 2.0
Dimensions and Weight
Dimensions W H D
(in millimeters)
25 290 210
Weight Approx. 650 g
Data for Specific Module
Number of outputs 8
Length of cable
• Shielded Max. 200 m
Voltages, Currents, Potentials
Supply voltage of the
electronics L+
24 VDC
Rated load voltage L+ 24 VDC
• Reverse polarity protection Yes
Isolation
• Between channels and
backplane bus
• Between the channels
• Between channels and
load voltage L+
Yes
No
Yes
Permitted potential difference
• Between the outputs (E
CM
)
• Between S– and M
ANA
(U
CM
)
• Between M
ANA
and
M
internal
(U
ISO
)
3 VDC
3 VDC
75 VDC/60 VAC
Insulation tested
• Between bus and L+/M
• Between bus and analog
section
• Between bus and chassis
ground
• Between analog section
and L+/M
• Between analog section
and chassis ground
• Between L+/M and chassis
ground
2120 VDC
2120 VDC
500 VDC
707 VDC
2120 VDC
2120 VDC
Current consumption
• From the backplane bus Max. 150 mA
• Power supply and load
voltage L+ (with rated load)
Max. 400 mA
• Power supply and load
voltage L+ (no load)
Max. 200 mA
Power dissipation of the
module
Typ. max. 9 W
Analog Value Generation
Resolution including sign 13 bits
Conversion time (per channel)
• In the ranges 1 V to 5 V
and 4 mA to 20 mA
420 s
• In all ranges 300 s
Basic response time of module
(all channels enabled)
• In the ranges 1 V to 5 V
and 4 mA to 20 mA
3.36 ms
• In all the other ranges 2.4 ms
Settling time
• For resistive load
• For capacitive load
• For inductive load
0.1 ms
3.5 ms
0.5 ms
Suppression of Interference, Limits of Error
Interference voltage suppression for f = n (f1 " 1%),
(f1 = interference frequency) n= 1.2 ...
• Common-mode
interference
(U
CM
< AC 3 V
ss
/50 Hz)
>60 dB
Crosstalk between the outputs
> 40 dB
Operational limit (in the entire temperature range, with
reference to the output range)
• Voltage outputs
– " 10 V
– 0 V to 10 V
– 1 V to 5 V
" 0.5 %
" 0.5 %
" 0.5 %
• Current outputs
– " 20 mA
– 4 mV to 20 mV
" 1%
" 1%
Basic error (operational limit at 25 °C, referred to the
output range)
• Voltage outputs
– " 10 V
– 0 V to 10 V
– 1 V to 5 V
" 0.5%
" 0.5%
" 0.5%
• Current outputs
– " 20 mA
– 0 mA to 20 mA
" 0.5%
" 0.5%
Temperature error (with
reference to the output range)
" 0.02% K
Linearity error (with reference
to the output range)
" 0.05%