COMMUNICATIONS / INTERFACES
MICROMASTER
MICROMASTER Vector
MIDIMASTER Vector
SIEMENS DA 64 – 2001/2002
Version C4 4/14
Parameter Function Range [factory setting]
MICROMASTER MICRO/MIDIMASTER Vector
P212 • 100 % setpoint 0.00 - 100.00 [100.00] 0.00 - 100.00 [100.00]
P220 Frequency cut-off 0 - 1 [0] 0 - 1 [0]
P321 Minimum analog frequency for analog
setpoint 2
- 0.00 - 650.00 [0.00]
P322 • Maximum analog frequency for analog
setpoint 2
- 0.00 - 650.00 [0.00]
P323 Analog input 2 type - 0 - 2 [0]
P386 • Sensorless Vector speed control loop
gain – proportional term
- 0.0 - 20.0 [1.0]
P387 Sensorless Vector speed control loop
gain – integral term
- 0.01 - 10.0 [1.0]
P720 • Direct input/output functions 0 - 1 [0] 0 - 7 [0]
P721 Analog input 1 voltage (V) 0.0 - 10.0 [-] 0.0 - 10.0 [-]
P722 • Analog output 1 current 1 (mA) - 0.0 - 20.0 [-]
P723 State of digital inputs 0 - 7 [-] 0 - 31 [-]
P724 • Relay output control 0 - 1 [0] 0 - 3 [0]
P725 Analog input 2 voltage (V) - 0.0 - 10.0 [-]
P726 • Analog output 2 current 2 (mA) - 0.0 - 20.0 [0] MIDI
P910 • LOCAL/USS mode 0 - 4 [0] 0 - 4 [0]
P922 Software version 0 - 9999 [-] 0 - 9999 [-]
P923 • Equipment system number 0 - 255 [0] 0 - 255 [0]
P930 Most recent fault code 0 - 9999 [-] 0 - 255 [-]
P931 Most recent warning type 0 - 9999 [-] 0 - 99 [-]
P944 Reset to factory default settings 0 - 1 [0] 0 - 1 [0]
P971 • EEPROM storage control 0 - 1 [1] 0 - 1 [1]
Table 15: Parameter list