Siemens EK 726 Series Manual de Serviço Página 9

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 120
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 8
INTRODUCTION
MICROMASTER
MICROMASTER Vector
MIDIMASTER Vector
SIEMENS DA 64 – 2002/2003
1/3 Version D
1.2 Technical data
Drive inverter MICROMASTER MICROMASTER
Vector
MIDIMASTER Vector
Line supply voltage
1-ph. 208 V – 240 V AC ±10%
3-ph. 208 V – 240 V AC ±10%
3-ph. 380 V - 500 V AC ±10%
3-ph. 208 V - 240 V AC ±10%
3-ph. 380 V - 500 V AC ±10%
3-ph. 525 V - 575 V AC ±15%
1-ph. 230 V AC
3-ph. 230 V AC
3-ph. 400 V AC
3-ph. 575 V AC
120 W – 3.0 kW
120 W – 4.0 kW
370 W – 7.5 kW
5.5 (VT 7,5) kW - 45 (VT 45) kW
11 (VT 15) kW - 75 (VT 90) kW
2.2 (VT 4) kW - 37 (VT 45) kW
Degree of protection IP20/NEMA1 IP21/NEMA1 or IP56
In conformance with EN 55011,
Class A for
1-ph. 230 V AC
3-ph. 230 V AC
3-ph. 400 V AC
3-ph. 575 V AC
Integrated filter
External filter
Integrated / external filter
xxx
xxx
Internal / external filter
Internal / external filter
xxx
In conformance with EN 55011,
Class B for
1-ph. 230 V AC
3-ph. 230 V AC
3-ph. 400 V AC
3-ph. 575 V AC
External filter
External filter
External filter
xxx
xxx
External filter
External filter
xxx
Temperature range 0 – 50°C 0 – 40°C
Control technique V/Hz Sensorless vector control, FCC, V/Hz
Overload capability
1
) 150% rated output
current
for 60 s
150% rated output current for 60 s
200% rated output current for 3 s
Protective functions
Undervoltage, overvoltage, overload, short-circuit, ground fault, motor failure, motor overtemperature, drive
inverter overtemperature
Max. motor cable length Refer to Section 3 Refer to Section 3
Frequency range 0 - 400 Hz 0 - 650 Hz 0 - 650 Hz
Setpoint resolution 0.05 Hz
Digital inputs
3, parameterizable
(19 functions)
6, parameterizable (24 functions)
Fixed frequencies 7 8
Ramp-up/ramp-down times 2
Relay outputs
1, parameterizable
110 V AC / 0.3 A
30 V DC / 1.0 A
2, parameterizable
240 V AC / 0.8 A
30 V DC / 2 A
Analog inputs 1 2
Analog outputs - 1, parameterizable 2, parameterizable
Serial interfaces RS485
Dynamic braking Compound braking Braking chopper External braking module
Internal technology controller PI PID
1
) The overload capability refers to the rated output currents of the MICROMASTER and MICROMASTER Vector drives as well as
the rated output currents for constant torque operation (CT) of the MIDIMASTER Vector. It is valid for a 5 minute load duty cycle.
This means that the drive units can have an overload condition of 50% for a total of 1 minute within a 5 minute period.
Table 1: Technical data