OPTIONS
MICROMASTER
MICROMASTER Vector
MIDIMASTER Vector
SIEMENS DA 64 – 2002/2003
6/11 Version D
6.3.3 MICROMASTER & MICROMASTER Vector (3-ph. 400V AC)+
Rated power
[KW]
Designation Drive inverter
IP20/21
Order No.
2% line reactor*
Order No.
4% line reactor*
Order No.
Output reactor**
Order No.
0.37 MM37/3 6SE9211-1DA40 6SE6400-3CC00-2AD0 - 6SE6400-3TC00-4AD0
0.37 MMV37/3 6SE3211-1DA40 6SE6400-3CC00-2AD0 - 6SE6400-3TC00-4AD0
0.55 MM55/3 6SE9211-4DA40 6SE6400-3CC00-2AD0 - 6SE6400-3TC00-4AD0
0.55 MMV55/3 6SE3211-4DA40 6SE6400-3CC00-2AD0 - 6SE6400-3TC00-4AD0
0.75 MM75/3 6SE9213-6DA40 6SE6400-3CC00-4AD0 - 6SE6400-3TC00-4AD0
0.75 MMV75/3 6SE3213-6DA40 6SE6400-3CC00-4AD0 - 6SE6400-3TC00-4AD0
1.1 MM110/3 6SE9212-7DA40 6SE6400-3CC00-4AD0 - 6SE6400-3TC00-4AD0
1.1 MMV110/3 6SE3212-2DA40 6SE6400-3CC00-4AD0 - 6SE6400-3TC00-4AD0
1.5 MM150/3 6SE9214-0DA40 6SE6400-3CC00-6AD0 - 6SE6400-3TC00-4AD0
1.5 MMV150/3 6SE3214-0DA40 6SE6400-3CC00-6AD0 - 6SE6400-3TC00-4AD0
2.2 MM220/3 6SE9215-8DB40 6SE6400-3CC01-0BD0 - 6SE6400-3TC01-0BD0
2.2 MM220/3F 6SE9215-8DB50 6SE6400-3CC01-0BD0 - 6SE6400-3TC01-0BD0
2.2 MMV220/3 6SE3215-8DB40 6SE6400-3CC01-0BD0 - 6SE6400-3TC01-0BD0
2.2 MMV220/3F 6SE3215-8DB50 6SE6400-3CC01-0BD0 - 6SE6400-3TC01-0BD0
3.0 MM300/3 6SE9217-3DB40 6SE6400-3CC01-0BD0 - 6SE6400-3TC01-0BD0
3.0 MM300/3F 6SE9217-3DB50 6SE6400-3CC01-0BD0 - 6SE6400-3TC01-0BD0
3.0 MMV300/3 6SE3217-3DB40 6SE6400-3CC01-0BD0 - 6SE6400-3TC01-0BD0
3.0 MMV300/3F 6SE3217-3DB50 6SE6400-3CC01-0BD0 - 6SE6400-3TC01-0BD0
4.0 MM400/3 6SE9221-0DC40 4EP3400-1US
(4EP3400-3US)
3x4EM4807-6CB 6SE3200-3TC03-2CD0
4.0 MM400/3F 6SE9221-0DC50 -- "-- -- "-- 6SE3200-3TC03-2CD0
4.0 MMV400/3 6SE3221-0DC40 -- "-- -- "-- 6SE3200-3TC03-2CD0
4.0 MMV400/3F 6SE3221-0DC50 -- "-- -- "-- 6SE3200-3TC03-2CD0
5.5 MM550/3 6SE9221-3DC40 4EP3500-0US
(4EP3600-8US)
4EP3700-7US
(4EP3800-8US)
6SE3200-3TC03-2CD0
5.5 MM550/3F 6SE9221-3DC50 -- "-- -- "-- 6SE3200-3TC03-2CD0
5.5 MMV550/3 6SE3221-3DC40 -- "-- -- "-- 6SE3200-3TC03-2CD0
5.5 MMV550/3F 6SE3221-3DC50 -- "-- -- "-- 6SE3200-3TC03-2CD0
7.5 MM750/3 6SE9221-5DC40 4EP3600-4US
(4EP3600-2US)
4EP3801-0US
(4EP3800-8US)
6SE3200-3TC03-2CD0
7.5 MM750/3F 6SE9221-5DC50 -- "-- -- "-- 6SE3200-3TC03-2CD0
7.5 MMV750/3 6SE3221-5DC40 -- "-- -- "-- 6SE3200-3TC03-2CD0
7.5 MMV750/3F 6SE3221-5DC50 -- "-- -- "-- 6SE3200-3TC03-2CD0
* Technical data refer to Chapter 3
6SE64... line reactors can be used for line impedances of ³ 1% and above and are comparable with 2% reactors.
The maximum line voltage when using the line reactors is 3-ph 380V - 480V +/-10% AC
For voltages above 480 V, the reactors in brackets should be used.
** Technical data refer to Chapter 3
f
puls
<= 4 kHz When using output reactors, the pulse frequency should be reduced to 4kHz (P076).
f
max
120Hz The maximum output frequency (f
max
~ 120Hz) depends on the ratio between the drive inverter output voltage, the
voltage drop across the output reactor (V
K
) and the motor being used.
The drive inverter can be over-dimensioned as an alternative to using an output reactor (refer to Chapter 3)
Comentários a estes Manuais