Welcome to the Siemens Simatic S7 (SI7) Power Tool. This program is your main
tool for configuring and troubleshooting the SI7 7.x driver.
This Online Help system provides conceptual information and instructions about the
SI7 Power Tool and is intended for use by anyone who wants to configure the driver
or use the Power Tool. This information system contains:
Supported hardware, software, and Siemens commands
Configuring the driver
Passing data from the driver to FIX
Accessing driver statistics
Troubleshooting the driver
Using the Power Tool
Optimizing the driver
To start using the SI7 information system, click the arrow button at the top of the
screen or make a selection from the contents or index.
Vista de página 0
1 2 3 4 5 6 ... 267 268

Resumo do Conteúdo

Página 1

Welcome to the Siemens Simatic S7 (SI7) Power Tool. This program is your main tool for configuring and troubleshooting the SI7 7.x driver. Th

Página 2 - Copyright

x Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reserved.

Página 3 - Contents

90 Siemens Simatic S7 Driver Online HelpOnce the SIMATIC NET is installed, your first step is to create a database of connections to use with your pro

Página 4

Chapter 7. Sample Configurations 91 [8] Select Generate Binary DB As from the File menu.[9] Enter a name for the binary database file you want to crea

Página 5

92 Siemens Simatic S7 Driver Online Help[4] Click the Properties button. When the Properties dialog box appears, click the Profibus tab.[5] Clear the

Página 6

Chapter 7. Sample Configurations 93 Industrial Ethernet to S7 300You can establish an Industrial Ethernet connection between your SCADA server and an

Página 7

94 Siemens Simatic S7 Driver Online HelpOnce you have connected the hardware together, install one of the following versions of SIMATIC NET if you are

Página 8

Chapter 7. Sample Configurations 95 Once the SIMATIC NET is installed, your first step is to create a database of connections for use with your proces

Página 9

96 Siemens Simatic S7 Driver Online Help[7] Enter a name for the database source file in the dialog box that appears.[8] Select Generate Binary DB As

Página 10

Chapter 7. Sample Configurations 97 [4] Click the Properties button. The Properties dialog box appears.[5] Click the S7 Protocol tab and select the S

Página 11 - 1. First-time Users

98 Siemens Simatic S7 Driver Online HelpOnce you install an interface card in your computer, you can begin to set up communication by cabling the SCAD

Página 12 - What is a Channel?

Chapter 7. Sample Configurations 99 Once the SIMATIC NET is installed, your first step is to create a database of connections to use with your process

Página 13 - What is a Datablock?

Chapter 1. First-time Users 1 1. First-time UsersWelcome! This section of the SI7 manual provides an introduction to 7.x drivers and OPC servers. It

Página 14 - What is a Timeout?

100 Siemens Simatic S7 Driver Online Help[7] Enter a name for the database source file in the dialog box that appears.[8] Select Generate Binary DB As

Página 15 - How Do Retries Work?

Chapter 7. Sample Configurations 101 [4] Click the Properties button. The Properties dialog box appears.[5] Click the S7 Protocol tab and select the

Página 16 - What is Signal Conditioning?

102 Siemens Simatic S7 Driver Online HelpCabling to the MPI Port on an S7 300SCADA ServerS7 300 PLCMPI PortProfibus cable

Página 17 - What is an Overrun?

Chapter 7. Sample Configurations 103 Cabling to the MPI Port on an S7 400NOTE: Do not cable more than one PLC to your computer when communicating thro

Página 18

104 Siemens Simatic S7 Driver Online HelpTo create the database for SIMATIC NET 5.x[1] Start the COML S7 application:[a] Select Simatic. A context me

Página 19

Chapter 7. Sample Configurations 105 [9] Enter a name for the binary database file you want to create and note the location of the file for later use.

Página 20

106 Siemens Simatic S7 Driver Online Help[5] Select the PG/PC is the only master on the bus checkbox.[6] Record the value listed in the Timeout field.

Página 21 - 3. Accessing Information

Chapter 7. Sample Configurations 107 To configure your local computer to communicate with SIMATIC NET v6.0[1] Program your PLC with Step 7. Save your

Página 22 - Using the Online Help Index

108 Siemens Simatic S7 Driver Online Help

Página 23 - “database blocks”

Chapter 8. Using the Power Tool 109 8. Using the Power ToolThe SI7 I/O Driver Power Tool is your main configuration utility for setting up and maintai

Página 24

2 Siemens Simatic S7 Driver Online HelpFor example, if your process hardware communicates using Industrial Ethernet or Profibus, you may need to speci

Página 25

110 Siemens Simatic S7 Driver Online HelpFrom Database ManagerSelect SI7 from the Drivers menu.From the System Configuration Utility (SCU)[1] Select S

Página 26 - Navigating the Online Help

Chapter 8. Using the Power Tool 111 See AlsoConfiguring the I/O Driver with the Power Tool | Adding and Modifying Channels | Adding and Modifying Devi

Página 27

112 Siemens Simatic S7 Driver Online HelpPower Tool Tree BrowserWhen you select an item in the Tree Browser, its properties display in the Properties

Página 28 - Using Online Help Buttons

Chapter 8. Using the Power Tool 113 Navigating in the Tree BrowserYou can navigate through the Tree Browser by selecting items with a mouse or by usin

Página 29

114 Siemens Simatic S7 Driver Online HelpProperties Viewer Displaying Channel Statistics PropertiesTo display the configuration properties for a drive

Página 30 - Printing from the Online Help

Chapter 8. Using the Power Tool 115 Using the Power Tool’s Main Toolbar The Power Tool’s Main toolbar is shown in the following figure: The Mai

Página 31

116 Siemens Simatic S7 Driver Online HelpThe Run-time toolbar contains buttons that are shortcuts to dialog boxes for viewing driver configurations an

Página 32 - Using the Favorites Tab

Chapter 8. Using the Power Tool 117 See AlsoStarting and Stopping the I/O Driver | Viewing Statistics | Setting up the Power Tool’s Environment | Sett

Página 33 - 4. How Do I?

118 Siemens Simatic S7 Driver Online HelpUsing Shortcut KeysThe following list shows the shortcut keys for working with the Power Tool:

Página 34 - Eliminating Excess Datablocks

Chapter 8. Using the Power Tool 119 The Status Bar The status bar displays Power Tool status messages. It is located under the Properties Viewer.

Página 35 - Chapter 4. How Do I? 25

Chapter 1. First-time Users 3 What is a Device?A device is a programmable logic controller (PLC), a remote terminal unit (RTU), or some other hardware

Página 36 - Hardware

120 Siemens Simatic S7 Driver Online HelpSetting the Statistics Refresh Rate The refresh rate determines how frequently the driver statistics update.T

Página 37 - To use Simulation Mode

Chapter 8. Using the Power Tool 121 Setting Defaults for I/O Driver Configuration File Name and Path The default path for the configuration file is th

Página 38

122 Siemens Simatic S7 Driver Online HelpSee AlsoUsing the Power Tool | Setting up the Power Tool’s Environment | Setting Default Values for Channels,

Página 39 - Chapter 4. How Do I? 29

Chapter 8. Using the Power Tool 123 [3] Complete the Advanced fields by making selections for the following fields:• Simulation Mode•Auto Create •Aut

Página 40 - Remotely

124 Siemens Simatic S7 Driver Online HelpTo connect to the server on the local machine[1] Start the SI7 I/O Driver Power Tool or select OLE Server fro

Página 41 - Chapter 4. How Do I? 31

Chapter 8. Using the Power Tool 125 [3] Click Yes if you want to try another server. If you cannot connect to the machine that the server is on and t

Página 42

126 Siemens Simatic S7 Driver Online Help[6] In the Target field, add one of the following command line parameters after SI7didw.exe, as shown in the

Página 43 - Chapter 4. How Do I? 33

Chapter 8. Using the Power Tool 127 [3] Change the line: [4] Save the file.The next time you start the Power Tool, the dialog box appears.

Página 44 - Datablocks using FIX or iFIX

128 Siemens Simatic S7 Driver Online Help

Página 45 - After the block write

Chapter 9. Configuring the I/O Driver with the Power Tool 129 9. Configuring the I/O Driver with the Power ToolOnce you start the Power Tool, you can

Página 46 - To restart the server

4 Siemens Simatic S7 Driver Online Help What is a Timeout?A timeout is the length of time the driver waits for a response from the process hard

Página 47 - 5. About the SI7 I/O Driver

130 Siemens Simatic S7 Driver Online HelpAdding and Modifying ChannelsChannels define communication paths between the process hardware and the SI7 dri

Página 48 - How the I/O Driver Works

Chapter 9. Configuring the I/O Driver with the Power Tool 131 To add a new device to your driver configuration[1] From the Tree Browser, select the ch

Página 49

132 Siemens Simatic S7 Driver Online Help[3] If the device does not respond, the driver repeats step 2 until it receives a response or it has exhauste

Página 50

Chapter 9. Configuring the I/O Driver with the Power Tool 133 the failed device, it ignores the Retries and only makes one attempt. If the attempt is

Página 51

134 Siemens Simatic S7 Driver Online HelpTo add a new datablock to your driver configuration[1] From the Tree Browser, select the device you want to a

Página 52

Chapter 9. Configuring the I/O Driver with the Power Tool 135 Specific address ranges depend on your process hardware. The following table lists addr

Página 53 - The SI7 I/O Driver Features

136 Siemens Simatic S7 Driver Online HelpValid Datablock Addresses *The amount of physical I/O installed in the PLC determines the maximum length o

Página 54

Chapter 9. Configuring the I/O Driver with the Power Tool 137 See AlsoAdding and Modifying DatablocksReading and Writing Text StringsThe SI7 driver re

Página 55

138 Siemens Simatic S7 Driver Online HelpWhen reading a STRING datablock, the following guidelines apply:• You cannot split a STRING datablock over mu

Página 56

Chapter 9. Configuring the I/O Driver with the Power Tool 139 Reading and Writing Digital ValuesThe SI7 driver requires you to use the BYTE data type

Página 57 - Automation Applications

Chapter 1. First-time Users 5 In the SI7 driver, you also need to configure a SIMATIC NET API timeout value called the global timeout. Like the drive

Página 58

140 Siemens Simatic S7 Driver Online HelpDouble Word and REAL memory uses a similar structure: Byte 0 Byte 1Byte 2

Página 59

Chapter 9. Configuring the I/O Driver with the Power Tool 141 Timer MemoryTimer memory is structured as follows: Possible values for bits 12 and

Página 60

142 Siemens Simatic S7 Driver Online HelpThese values are used by multiplying the time resolution to the Binary Coded Decimal (BCD) value in bits 0-11

Página 61

Chapter 9. Configuring the I/O Driver with the Power Tool 143 Valid Entries When using the ASCII or STRING data type to read and write text, specifi

Página 62 - Feature: Phasing Poll Rates

144 Siemens Simatic S7 Driver Online HelpAnalog Register blocks can be configured to use driver datablocks with the following data types: INT, WORD, D

Página 63 - Feature: QuickFail Logic

Chapter 9. Configuring the I/O Driver with the Power Tool 145 The access time in the driver is typically used with register blocks in the process data

Página 64

146 Siemens Simatic S7 Driver Online HelpRefer to Using Primary and Secondary Poll Rates with Access Time for additional examples of primary and secon

Página 65

Chapter 9. Configuring the I/O Driver with the Power Tool 147 Example 1PollRec1Primary Poll Rate = 10 secondsSecondary Poll Rate = DisabledAccess Time

Página 66 - Feature: Using Latched Data

148 Siemens Simatic S7 Driver Online HelpNOTE: Specifying an access time that is shorter than a block’s scan time forces the driver to poll at the sec

Página 67

Chapter 9. Configuring the I/O Driver with the Power Tool 149 In situations where the mode of transmission is slow, such as radio or telephone communi

Página 68 - SI7Drv REGSERVICE

6 Siemens Simatic S7 Driver Online HelpSee AlsoUnderstanding Device Timing Properties: Reply Timeout, Retry, and Delay TimeWhat is Signal Conditioning

Página 69

150 Siemens Simatic S7 Driver Online HelpSee AlsoFeature: Phasing Poll Rates | Adding and Modifying Datablocks | Understanding Datablock Timing Proper

Página 70 - SI7Drv REGSERVER

Chapter 9. Configuring the I/O Driver with the Power Tool 151 The Power Tool stores the default driver, channel, device, and datablock properties in t

Página 71 - Feature: Block Writes

152 Siemens Simatic S7 Driver Online HelpNOTE: Certain fields and controls cannot be set in the Templates dialog box. These fields/controls are eithe

Página 72 - !Send:DataBlockName

Chapter 9. Configuring the I/O Driver with the Power Tool 153 Channel Header — contains a list of all the channel properties. The channel header must

Página 73

154 Siemens Simatic S7 Driver Online HelpSample .CSV file displayed in a text editor Report Header[SI7 7.20 I/O Driver Configuration Report, Friday Ju

Página 74 - Supported Hardware

Chapter 9. Configuring the I/O Driver with the Power Tool 155 You can import a .CSV file from the Power Tool or the I/O Server. Regardless of the met

Página 75

156 Siemens Simatic S7 Driver Online Help

Página 76 - Required Software

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications157 10. Configuring the I/O Driver from FIX/iFIX ApplicationsUse the following links

Página 77

158 Siemens Simatic S7 Driver Online HelpTo configure the driver from Database Manager, you must know the following information about the driver:

Página 78 - Programming Software

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications159 Entering Driver Information in Database ManagerYou can configure one or more data

Página 79 - 6. Hardware Setup

Chapter 1. First-time Users 7 Signal conditioning is driver-dependent. Consequently, one driver may support one type of scaling, but not another. See

Página 80

160 Siemens Simatic S7 Driver Online HelpDatabase Block Dialog Box [3] Enter a name in the Tag Name field.[4] Complete the driver fields

Página 81 - Chapter 6. Hardware Setup 71

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications161 I/O Driver FieldsRefer to the following topics for valid entries for each field:•

Página 82 - S7 300 CPU with a CP342-5

162 Siemens Simatic S7 Driver Online HelpNOTE: The SI7 driver must appear in the SCU’s Configured I/O Driver list box for Database Manager to recogniz

Página 83 - (no communication module)

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications163 DEVICE_NAME:ADDRESS[:BIT]Where: If you enter an I/O address not defined by a dat

Página 84 - Configuring the Hardware

164 Siemens Simatic S7 Driver Online HelpYou can enter the following special addresses into the I/O Address field of a Digital Output or Analog Output

Página 85 - Programming the Hardware

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications165 Special Address Events !SWITCH:DEVICE Toggles the communication path between t

Página 86

166 Siemens Simatic S7 Driver Online HelpSee AlsoForcing a Switch Between Primary and Back-up Channels or Devices using FIX or iFIX | Enabling or Disa

Página 87 - Chapter 6. Hardware Setup 77

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications167 SI7 Supported Signal Conditioning Types IMPORTANT: Most signal conditioning typ

Página 88

168 Siemens Simatic S7 Driver Online HelpParameters for No Signal Conditioning See AlsoSpecifying Signal Conditioning in Database Ma

Página 89 - Chapter 6. Hardware Setup 79

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications169 See AlsoSpecifying Signal Conditioning in Database Manager12AL Signal Conditionin

Página 90

8 Siemens Simatic S7 Driver Online Help Datablocks 1 to 101 second2 seconds3 seconds4 secondsSent to process hardwareSent to process hardwareSent

Página 91 - Chapter 6. Hardware Setup 81

170 Siemens Simatic S7 Driver Online HelpParameters for 12AL Signal Conditioning Description 12-bit binary number.Input Range 0 – 4095.Scal

Página 92

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications171 See AlsoSpecifying Signal Conditioning in Database Manager15BN Signal Conditionin

Página 93 - 7. Sample Configurations

172 Siemens Simatic S7 Driver Online HelpSee AlsoSpecifying Signal Conditioning in Database Manager15AL Signal Conditioning Signal conditioning define

Página 94

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications173 Parameters for 15AL Signal Conditioning Description 15-bit binary numb

Página 95

174 Siemens Simatic S7 Driver Online HelpSee AlsoSpecifying Signal Conditioning in Database ManagerLIN Signal Conditioning Signal conditioning defines

Página 96

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications175 Parameters for LIN Signal Conditioning Description 8-bit or 16-bit bin

Página 97

176 Siemens Simatic S7 Driver Online HelpSee AlsoSpecifying Signal Conditioning in Database Manager3BCD Signal Conditioning Signal conditioning define

Página 98 - Profibus to S7 400

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications177 Read AlgorithmReads from a 3-digit BCD register. The Raw_value is then separated

Página 99

178 Siemens Simatic S7 Driver Online HelpSee AlsoSpecifying Signal Conditioning in Database Manager4BCD Signal Conditioning Signal conditioning define

Página 100 - To create the database

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications179 See AlsoSpecifying Signal Conditioning in Database Manager13BN Signal Conditionin

Página 101

Chapter 2. First-time 7.x Driver Users 9 2. First-time 7.x Driver Users The following links provide an introduction to 7.x I/O drivers and are intende

Página 102

180 Siemens Simatic S7 Driver Online HelpParameters for 13BN Signal Conditioning Description 13-bit binary number.Input Range 0 – 8191.Scali

Página 103 - Industrial Ethernet to S7 300

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications181 See AlsoSpecifying Signal Conditioning in Database Manager13AL Signal Conditionin

Página 104

182 Siemens Simatic S7 Driver Online HelpSee AlsoSpecifying Signal Conditioning in Database Manager8BN Signal Conditioning Signal conditioning defines

Página 105

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications183 See AlsoSpecifying Signal Conditioning in Database Manager8AL Signal Conditioning

Página 106

184 Siemens Simatic S7 Driver Online HelpParameters for 8AL Signal Conditioning Description 8-bit binary number.Input Range 0 – 255.Scaling

Página 107 - Industrial Ethernet to S7 400

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications185 See AlsoSpecifying Signal Conditioning in Database ManagerS5TI and TBCD Signal Co

Página 108

186 Siemens Simatic S7 Driver Online HelpRead AlgorithmReads from an S5 Time register. Bits 11 to 0 of the Raw_value are then separated into three ni

Página 109

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications187 See AlsoSpecifying Signal Conditioning in Database ManagerS5CO Signal Conditionin

Página 110

188 Siemens Simatic S7 Driver Online HelpOn a read, values for the activity bit, the fault bit, and the overflow bit can be 0 or 1. Typically, the va

Página 111 - Using the MPI Port

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications189 For example, if you configure a datablock with a BYTE data type and then select I

Página 112 - Profibus cable

CopyrightProprietary NoticeThe manual and software contain confidential information which represents trade secrets of GE FanucInternational, Inc. and/

Página 113 - S7 400 PLC

10 Siemens Simatic S7 Driver Online Help

Página 114

190 Siemens Simatic S7 Driver Online HelpSee AlsoSpecifying Signal Conditioning in Database Manager | Specifying I/O Addresses in Database Manager | S

Página 115

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications191 Verifying New Datablocks Created in Database ManagerWhen you create a datablock i

Página 116 - Using SIMATIC NET v6.0

192 Siemens Simatic S7 Driver Online HelpThe Power Tool Tree Browser initially displays:

Página 117

Chapter 10. Configuring the I/O Driver from FIX/iFIX Applications193 Press the F5 key to refresh the Tree Browser, and the Tree Browser displays:And t

Página 118

194 Siemens Simatic S7 Driver Online HelpSaving Datablocks Created in Database Manager to the Configuration FileCreating a datablock with Database Man

Página 119 - 8. Using the Power Tool

Chapter 11. Running the I/O Driver 195 11. Running the I/O DriverOnce you configure the driver, you can start it running. Running the driver helps yo

Página 120 - From Database Manager

196 Siemens Simatic S7 Driver Online HelpTo start the I/O driver from the I/O Driver Power Tool[1] Specify a default path and configuration file name

Página 121 - Interface

Chapter 11. Running the I/O Driver 197 To start the SI7 I/O driver from SCU[1] Start the System Configuration Utility (SCU):[a] Select Programs from t

Página 122

198 Siemens Simatic S7 Driver Online HelpSetting the I/O Driver for Automatic Startup in FIX/iFIX You can configure a driver to start automatically by

Página 123

Chapter 11. Running the I/O Driver 199 [6] Enter the following command lines as needed, separated by a space: [7] Select the Background option but

Página 124

Chapter 3. Accessing Information 11 3. Accessing InformationYou can access the information system using one of the following methods:

Página 125 - Help Topics

200 Siemens Simatic S7 Driver Online Helpconfiguration file to match the name of your SCADA server. For example, if you change the name of the SCADA

Página 126

Chapter 11. Running the I/O Driver 201 Stopping the I/O DriverYou can stop the SI7 driver in several different ways.To stop the I/O driver manually fr

Página 127

202 Siemens Simatic S7 Driver Online HelpViewing StatisticsUse the following links to display information about SI7 driver statistics: • Viewing I/O

Página 128 - Using Shortcut Keys

Chapter 11. Running the I/O Driver 203 See AlsoUnderstanding the Power Tool’s Graphic Interface | Adding and Modifying Channels | Tools for Troublesho

Página 129 - The Status Bar

204 Siemens Simatic S7 Driver Online HelpUnderstanding Overruns An overrun occurs when the driver attempts to read more data from the process hardwar

Página 130 - To set the refresh rate

Chapter 11. Running the I/O Driver 205 Assume that at this setting, the driver can poll 5 datablocks on the device per second. If you configure 10 da

Página 131

206 Siemens Simatic S7 Driver Online HelpYou may be able to prevent overruns by phasing datablocks. Refer to Using Phasing with Poll Rates for detail

Página 132 - Making Advanced Settings

Chapter 12. Checking Communication 207 12. Checking CommunicationYou can verify that communication between FIX/iFIX software and the process hardware

Página 133

208 Siemens Simatic S7 Driver Online Help[7] Save and exit the SCU. [8] Start or restart FIX/iFIX.[9] Start the SI7 Power Tool:[a] Select Programs fr

Página 134

Chapter 12. Checking Communication 209 [3] Select Analog Input from the dialog box that appears and click OK.[4] Enter a name for the database block a

Página 135

12 Siemens Simatic S7 Driver Online HelpUsing the Online Help IndexThe SI7 Online Help provides an index to all conceptual and reference topics. This

Página 136

210 Siemens Simatic S7 Driver Online Help

Página 137 - From... To

Chapter 13. Optimizing Your System 211 13. Optimizing Your SystemSelect from the following topics for tips on optimizing your process. • Optimizi

Página 138

212 Siemens Simatic S7 Driver Online HelpYou should periodically start the I/O Driver Tool, examine the driver configuration datablock address propert

Página 139

Chapter 13. Optimizing Your System 213 Decreasing unnecessary stress on your systemClean up datablocks that you are not using for your process control

Página 140 - Adding and Modifying Devices

214 Siemens Simatic S7 Driver Online Help

Página 141 - Retry, and Delay Time

Chapter 14. Troubleshooting 215 14. TroubleshootingUse the following links to troubleshoot any difficulties you may encounter: • The Mos

Página 142

216 Siemens Simatic S7 Driver Online HelpThe Most Common I/O Driver ProblemsSome of the most common problems people encounter when setting up and usin

Página 143

Chapter 14. Troubleshooting 217 The Statistics in Mission ControlMission Control is the main FIX/iFIX tool for monitoring background tasks, such as SA

Página 144

218 Siemens Simatic S7 Driver Online HelpThe Alarm History WindowBecause the I/O driver reports event messages to the Alarm History application in FIX

Página 145

Chapter 14. Troubleshooting 219 The options in the program’s View menu let you choose the types of messages to display. The message priority is:[1] E

Página 146

Chapter 3. Accessing Information 13 To find a topic using the full-text search[1] Select Help Topics from the Power Tool’s Help menu to display the SI

Página 147

220 Siemens Simatic S7 Driver Online HelpAnswers to Common QuestionsUse the following links to receive answers to common questions and problems: •

Página 148

Chapter 14. Troubleshooting 221 • Automatic driver startup does not work. • I have a high timeout count. • Why am I receiving the error Invalid A

Página 149

222 Siemens Simatic S7 Driver Online HelpIf the driver still does not loadRename the default configuration file so the driver loads a blank configurat

Página 150

Chapter 14. Troubleshooting 223 See AlsoAutomatic driver startup does not work | The driver does not load | Setting the I/O Driver for Automatic Start

Página 151 - Real/Float Memory

224 Siemens Simatic S7 Driver Online HelpIf you are receiving error numbers in the device statistics Errors field• Examine the network interface card

Página 152 - Understanding Data Types

Chapter 14. Troubleshooting 225 [6] If you are running the driver with FIX or iFIX, make sure you have a configuration file named nodename.SI7, where

Página 153

226 Siemens Simatic S7 Driver Online HelpThe driver communicates to some but not all of my devicesIf you are receiving errors in the device statistics

Página 154 - Access Time

Chapter 14. Troubleshooting 227 Power Tool[1] Verify that each datablock address is valid and exists. The most common error for datablocks is request

Página 155

228 Siemens Simatic S7 Driver Online HelpIf you cannot see the remote server from Microsoft Explorer or by using the Ping programYou have a networking

Página 156

Chapter 14. Troubleshooting 229 If this is not the problem, you may have the Latch Data option enabled while experiencing a communication failure. To

Página 157

14 Siemens Simatic S7 Driver Online HelpDefining Search TermsThe AND, OR, NOT, and NEAR operators enable you to precisely define your search by creati

Página 158 - Using Phasing with Poll Rates

230 Siemens Simatic S7 Driver Online Help[6] Verify that the SCU is configured to start the IOCNTRL program with the command line parameter /a in the

Página 159

Chapter 14. Troubleshooting 231 See AlsoUnderstanding Device Timing Properties: Reply Timeout, Retry, and Delay Time | Viewing Device Statistics | Add

Página 160

232 Siemens Simatic S7 Driver Online HelpTo make sure you receive driver messages in Alarm History[1] Shut down FIX/iFIX and the I/O Driver Power Tool

Página 161

Chapter 14. Troubleshooting 233 [3] Specify a default path and configuration file name for the driver:[a] Select Setup from the Options menu. The Set

Página 162 - Using I/O Driver Report Files

234 Siemens Simatic S7 Driver Online HelpI have a high timeout count You can perform several steps to determine what is causing a high timeout count

Página 163

Chapter 14. Troubleshooting 235 With this data type, valid addresses occur on four-byte boundaries because REALs require four bytes for each value.NOT

Página 164

236 Siemens Simatic S7 Driver Online HelpTo print data from the datascope[1] Select Pause from the Run menu.[2] Press Alt + Shift + Print Scrn to copy

Página 165

Chapter 14. Troubleshooting 237 To view messages that might be generated by the driver[1] Start the Event Viewer:[a] Select Programs from the Start me

Página 166

238 Siemens Simatic S7 Driver Online HelpError Codes SI7 error codes display in the Last Error field of the Power Tool’s datablock statistics. The dr

Página 167 - Applications

Chapter 14. Troubleshooting 239 See AlsoTools for Troubleshooting the SI7 I/O Driver | Getting Technical Support | Supported Protocols | Supported Har

Página 168

Chapter 3. Accessing Information 15 Match similar words – Enables you to include minor grammatical variations for the phrase you search. For example,

Página 169

240 Siemens Simatic S7 Driver Online HelpBy [email protected] for the process hardwareBy World Wide WebVisit Siemens Energy &

Página 170 -

Chapter 15. Creating Custom Client Applications 241 15. Creating Custom Client ApplicationsThe SI7 I/O Server is an OLE application you can control pr

Página 171

242 Siemens Simatic S7 Driver Online HelpSee AlsoFeature: Configuring the Driver from Custom COM/OLE Automation ApplicationsCreating a Custom Applicat

Página 172 - Device Name

Chapter 15. Creating Custom Client Applications 243 To get started creating a configuration application with C or C++[1] Import the type library by ad

Página 173 - DEVICE_NAME:ADDRESS[:BIT]

244 Siemens Simatic S7 Driver Online HelpFor an explanation of this syntax, refer to Specifying I/O Addresses in Database Manager.If your OPC client s

Página 174 - !SEND:DATABLOCK

Chapter 16. Glossary 245 16. GlossaryThe following terms are used in the I/O Driver Power Tool. Use these definitions to help understand the explanat

Página 175

246 Siemens Simatic S7 Driver Online HelpProcess database block — individual units of instructions that receive, verify, manipulate, and output proces

Página 176 - Manager

© 2002 Intellution®, Inc. All Rights Reserved Index 247 IndexSymbols!MODE 164!POLL 164!SEND 35, 61, 164!SWITCH 164Numerics12AL signal

Página 177 - NONE Signal Conditioning

248 Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reservedbackup reply timeout 131bad data 228binary files 1

Página 178 - 12BN Signal Conditioning

© 2002 Intellution®, Inc. All Rights Reserved Index 249 creating datablocks in FIX Database Manager 28,190creating datablocks with FIX 158cre

Página 179 - 12AL Signal Conditioning

16 Siemens Simatic S7 Driver Online HelpTo use the Table of Contents[1] Select Help Topics from the Power Tool’s Help menu to display the SI7 Online H

Página 180

250 Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reserveddiagnostics 62differences between 6.x and 7.x drivers

Página 181 - 15BN Signal Conditioning

© 2002 Intellution®, Inc. All Rights Reserved Index 251 eliminating extra datablocks 24enabling block writes 61enabling channel outputs 1

Página 182 - 15AL Signal Conditioning

252 Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reservedhardware errors 203hardware options 143, 189help 1

Página 183

© 2002 Intellution®, Inc. All Rights Reserved Index 253 online help (continued)display options 18favorites tab 22index 12locating related

Página 184 - LIN Signal Conditioning

254 Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reservedprogramming hardware 75protocols 66Qquality statistics

Página 185

© 2002 Intellution®, Inc. All Rights Reserved Index 255 scaling data 166scan timesreceiving old data 228using with poll rates 24SCUautoma

Página 186 - 3BCD Signal Conditioning

256 Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reservedstatistics (continued)device overruns 203device retries

Página 187

© 2002 Intellution®, Inc. All Rights Reserved Index 257 troubleshooting (continued)error numbers 238loading drivers 222loading drivers with F

Página 188 - 4BCD Signal Conditioning

258 Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reserved

Página 189 - 13BN Signal Conditioning

Chapter 3. Accessing Information 17 appropriate option, you can press F1 to display a more complete description in a pop-up window. This window inclu

Página 190

18 Siemens Simatic S7 Driver Online HelpUsing Online Help ButtonsThe following buttons are displayed at the top of the Online Help window:

Página 191 - 13AL Signal Conditioning

Chapter 3. Accessing Information 19 See AlsoNavigating the Online Help | Determining Your Location within the Online Help | Printing from the Online H

Página 192 - 8BN Signal Conditioning

© 2002 Intellution®, Inc. All Rights Reserved. Contents iii 1. First-time Users ...

Página 193 - 8AL Signal Conditioning

20 Siemens Simatic S7 Driver Online HelpSee AlsoUsing the Online Help Table of Contents | Navigating the Online Help | Using Online Help Buttons Print

Página 194

Chapter 3. Accessing Information 21 [3] Go to http://www.intellution.com/products/fixiodrivers/showdrivers.asp?objid=866. [4] Click the link Download

Página 195

22 Siemens Simatic S7 Driver Online HelpNOTE: You cannot copy graphics from the SI7 Online Help.Using the Favorites Tab You can create a list of the

Página 196

Chapter 4. How Do I? 23 4. How Do I?Use the following links to learn how to:• Choose poll rates.• Eliminate excess datablocks.• Set up for remote conf

Página 197 - S5CO Signal Conditioning

24 Siemens Simatic S7 Driver Online HelpChoosing Poll RatesMake the datablock’s poll rate faster than the scan time. For example, if you have a datab

Página 198

Chapter 4. How Do I? 25 To eliminate excess datablocks[1] Export the current driver configuration file by saving it as a .CSV file. The CSV file serv

Página 199 - Data Type

26 Siemens Simatic S7 Driver Online HelpSetting up for Remote Configuration and ControlThe SI7 I/O Server (driver) configures the necessary remote set

Página 200 - Database Manager

Chapter 4. How Do I? 27 To use the Enable option[1] In the I/O Driver Power Tool Tree Browser, select the channel, device, or datablock you want to di

Página 201

28 Siemens Simatic S7 Driver Online HelpSee AlsoFeature: Enabling or Disabling Individual Channels, Devices, and DatablocksCreating Reports of my Driv

Página 202

Chapter 4. How Do I? 29 See AlsoOverview: Creating Datablocks Inside FIX/iFIX ApplicationsConfiguring a Driver for Demand PollingBy entering a special

Página 203

iv Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reserved.4. How Do I?...

Página 204

30 Siemens Simatic S7 Driver Online HelpPolling the Device only when Data is Being AccessedTo poll the device only when data is being accessed[1] From

Página 205 - 11. Running the I/O Driver

Chapter 4. How Do I? 31 The I/O Server re-registers every time you double-click the I/O Server icon or use a shortcut to open it from the desktop or t

Página 206

32 Siemens Simatic S7 Driver Online HelpSee AlsoFeature: Remote Control and Configuration | Setting Up the SI7 I/O Server ConnectionSetting up Securit

Página 207

Chapter 4. How Do I? 33 You can grant everyone access to the SI7 Server using the Windows utility, DCOMCNFG.EXE, for configuring DCOM applications. D

Página 208

34 Siemens Simatic S7 Driver Online HelpForcing a Switch Between Primary and Back-up Channels or Devices using FIX or iFIX You can force the driver to

Página 209 - SI7 - Siemens Simatic S7 7.x

Chapter 4. How Do I? 35 Sending Multiple Writes to a DatablockYou can write data to various registers in the hardware at one time using the Block Writ

Página 210

36 Siemens Simatic S7 Driver Online HelpRunning the Driver in Simulation Mode You can run the driver in simulation mode by enabling the option in the

Página 211 - Stopping the I/O Driver

Chapter 5. About the SI7 I/O Driver 37 5. About the SI7 I/O DriverThe Intellution SI7 I/O version 7.x I/O driver provides the interface and communicat

Página 212 - Viewing Statistics

38 Siemens Simatic S7 Driver Online HelpYou can also view and modify driver properties with a custom client application developed specifically for you

Página 213 - Viewing Datablock Statistics

Chapter 5. About the SI7 I/O Driver 39 I/O LibraryNIODLLOPCServerDLLI/O DriverPowerToolCommonMemoryDLLSignalConditionalDLLI/O Driver ServerProcessCo

Página 214 - Understanding Overruns

© 2002 Intellution®, Inc. All Rights Reserved. Contents v Feature: Using Simulation Mode ...

Página 215 - 4 seconds

40 Siemens Simatic S7 Driver Online Help[1] I/O ServerIs the I/O driver core. The I/O Server contains objects and interfaces that perform the followi

Página 216 - Understanding Data Quality

Chapter 5. About the SI7 I/O Driver 41 [5] Common Memory DLLBuilds common memory, exposes its functionality to the Server and the NIO DLL, and stores

Página 217 - 12. Checking Communication

42 Siemens Simatic S7 Driver Online Help[13] Process HardwareIncludes any type of supported I/O device that controls a process.[14] SIMATIC NETProvide

Página 218

Chapter 5. About the SI7 I/O Driver 43 The SI7 I/O Driver FeaturesIn addition to performance improvements, the SI7 driver: • Supports OLE for P

Página 219

44 Siemens Simatic S7 Driver Online HelpSee AlsoAbout the SI7 I/O Driver | How the I/O Driver WorksFeature: Using OLE for Process Control (OPC) OLE

Página 220

Chapter 5. About the SI7 I/O Driver 45 The code that your vendor writes defines the difference between servers and specifies the following server info

Página 221 - 13. Optimizing Your System

46 Siemens Simatic S7 Driver Online HelpFeature: Creating Datablocks Automatically in Database Manager By enabling the Auto Create option in the I/O

Página 222

Chapter 5. About the SI7 I/O Driver 47 IMPORTANT: Intellution does not recommend the use of the Auto Create option when the Hardware Options field in

Página 223 - See Also

48 Siemens Simatic S7 Driver Online HelpYour driver may include a custom Visual Basic application. You can use this application in place of the Power

Página 224

Chapter 5. About the SI7 I/O Driver 49 Refer to the following topics for a description of the Power Tool and how to use it to configure your driver:•

Página 225 - 14. Troubleshooting

vi Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reserved.Industrial Ethernet to S7 400 ...

Página 226

50 Siemens Simatic S7 Driver Online HelpTo install the Power Tool for remote communication[1] Insert the I/O Drivers and OPC Server CD into the remote

Página 227

Chapter 5. About the SI7 I/O Driver 51 Feature: Using Exception-Based ProcessingIntellution version 7.x drivers support exception-based processing wh

Página 228

52 Siemens Simatic S7 Driver Online HelpFeature: Using Secondary Poll RatesWith the SI7 I/O driver, you can specify a secondary poll rate. The drive

Página 229

Chapter 5. About the SI7 I/O Driver 53 Disable a channel if:You remove devices on a channel for repair or maintenance and do not want to display error

Página 230 - Answers to Common Questions

54 Siemens Simatic S7 Driver Online HelpHow It WorksThe driver polls a datablock on the device and experiences a communication timeout. The driver at

Página 231 - The driver does not load

Chapter 5. About the SI7 I/O Driver 55 PurposeTypically, when a message fails because of a timeout, the cause is a communication problem with the devi

Página 232

56 Siemens Simatic S7 Driver Online HelpSimulating a connection to the process hardware is accomplished by writing values directly to the datablocks t

Página 233 - To display driver statistics

Chapter 5. About the SI7 I/O Driver 57 Feature: Time/Date Stamp for Data and AlarmsIntellution version 7.x I/O drivers record the time and date when

Página 234

58 Siemens Simatic S7 Driver Online HelpBefore you register the I/O Server to run as a service, follow these steps to ensure that it is not currently

Página 235

Chapter 5. About the SI7 I/O Driver 59 The dialog box allows the user to select one of these accounts when registering the SI7 driver to run as a serv

Página 236

© 2002 Intellution®, Inc. All Rights Reserved. Contents vii Understanding Datablock Timing Properties: Rate, Phase, and Access Time... 144Using P

Página 237 - Power Tool

60 Siemens Simatic S7 Driver Online Helpsystem. For example, to determine Administrator privileges in Windows 2000, select Administrative Tools from

Página 238

Chapter 5. About the SI7 I/O Driver 61 Feature: Block WritesBlock writes let you send data to various registers in the hardware at one time by using

Página 239

62 Siemens Simatic S7 Driver Online HelpTo send block writes through FIX/iFIX[1] Enable block writes in the datablock you want to use.[2] Create a Dig

Página 240 - My message rate is slow

Chapter 5. About the SI7 I/O Driver 63 Using the Data MonitorThe SI7 I/O driver also supports a data monitor. This tool lets you view the contents of

Página 241

64 Siemens Simatic S7 Driver Online HelpSupported Hardware The SI7 I/O driver works with the following PLCs: • S7-300 PLC• CPU 312 IFM•CP

Página 242

Chapter 5. About the SI7 I/O Driver 65 Supported Communication ModulesThe SI7 driver supports the following communication modules in an S7-300 or S7-4

Página 243

66 Siemens Simatic S7 Driver Online HelpSupported Interface CardsThe SI7 driver supports the following interface cards installed in your SCADA server:

Página 244 - I have a high timeout count

Chapter 5. About the SI7 I/O Driver 67 Human-Machine Interface (HMI) Software Use one of the following HMI software packages: • FIX for Window

Página 245 - Using the Datascope

68 Siemens Simatic S7 Driver Online HelpProgramming SoftwareYou can program your process hardware to execute programs with your process hardware'

Página 246 - Using the Event Viewer

Chapter 6. Hardware Setup 69 6. Hardware SetupUse the following links to guide you in setting up your process hardware: • Overview: Configuring the S

Página 247

viii Siemens Simatic S7 Driver Online Help © 2002 Intellution®, Inc. All Rights Reserved.Saving Datablocks Created in Database Manager to the Configu

Página 248 - Error Codes

70 Siemens Simatic S7 Driver Online HelpOverview: Configuring the SI7 DriverThe following is a general overview of the steps necessary for setting up

Página 249 - Getting Technical Support

Chapter 6. Hardware Setup 71 See AlsoHow the I/O Driver Works | Supported Hardware | Supported Protocols | Required Software | CablingSetting up Your

Página 250

72 Siemens Simatic S7 Driver Online HelpProfibus Cabling Be sure your Profibus cables are properly terminated. Be sure your Profibus cables are pro

Página 251

Chapter 6. Hardware Setup 73 Be sure your Profibus cables are properly terminated.SCADA server with a Profibus CP 5613,CP 5611, or CP 5412 interface c

Página 252 - Visual Basic

74 Siemens Simatic S7 Driver Online HelpIndustrial Ethernet Cabling Configuring the HardwareIn order to establish communication with the SI7 driver,

Página 253 - __uuidof()

Chapter 6. Hardware Setup 75 Programming the HardwareYou can program your process hardware to execute programs with your process hardware's progr

Página 254

76 Siemens Simatic S7 Driver Online HelpModifying the Process DatabaseYou must also modify the process database because, with the SI7 driver, digital

Página 255 - 16. Glossary

Chapter 6. Hardware Setup 77 Differences Between 6.x and 7.x DriversMany of the differences between 6.x and 7.x drivers are new features. To learn mo

Página 256

78 Siemens Simatic S7 Driver Online HelpNOTE: A configuration file named nodename.SI7 is saved in the root Dynamics directory when you install the dri

Página 257 - Numerics

Chapter 6. Hardware Setup 79 Exporting a S_7 6.x Driver Configuration If you are upgrading from the S_7 6.x driver, you can export your 6.x driver con

Página 258

© 2002 Intellution®, Inc. All Rights Reserved. Contents ix The driver communicates to some but not all of my devices...

Página 259

80 Siemens Simatic S7 Driver Online HelpModifying the Process DatabaseOnce your 7.x driver configuration is imported and communicating with the proces

Página 260

Chapter 6. Hardware Setup 81 Once you modify all driver and database configurations, be sure to also correct links to any Digital Register blocks you

Página 261

82 Siemens Simatic S7 Driver Online HelpChoosing a Method for Configuring Your DriverIf you are not upgrading from the S_7 6.x driver or migrating fro

Página 262

Chapter 7. Sample Configurations 83 7. Sample ConfigurationsThe sample configurations provided in this document are for informational purposes only.

Página 263

84 Siemens Simatic S7 Driver Online Help After cabling the hardware, install one of the following versions of SIMATIC NET if you are using SIMATIC N

Página 264

Chapter 7. Sample Configurations 85 Once the SIMATIC NET is installed, your first step is to create a database of connections to use with your process

Página 265

86 Siemens Simatic S7 Driver Online Help[8] Select Generate Binary DB As from the File menu.[9] Enter a name for the binary database file you want to

Página 266

Chapter 7. Sample Configurations 87 [4] Click the Properties button. When the Properties dialog box appears, click the Profibus tab.[5] Clear the PG/

Página 267

88 Siemens Simatic S7 Driver Online HelpProfibus to S7 400You can establish a Profibus connection between your SCADA server and an S7 400 PLC. To beg

Página 268

Chapter 7. Sample Configurations 89 After cabling the hardware, install one of the following versions of SIMATIC NET if you are using SIMATIC NET v5.x