Operating recipes
10.4 Recipe application
TP 270, OP 270, MP 270B (WinCC flexible)
Operating Instructions, Edition 03/2004, 6AV6691-1DD01-0AB0
10-7
These configuration settings are made under "Settings" in the property view:
Configuration 1: Recipe without "Synchronize tags"
Data of a data record that has been read are only displayed and can only be edited in the
recipe view. Using these same tags outside of the recipe view does not affect their values.
Configuration 2: Recipe with "Synchronize tags" and with "Tags offline"
The "Synchronize tags" option is used to specify that the data of a data record read from the
controller or storage medium are to be written to or read from the tags you have configured
for the recipe.
The "Offline" option ensures that the input data are written to the tags without being
transferred directly to the controller.
Configuration 3: Recipe with "Synchronize tags" and without "Tags offline"
The "Synchronize tags" option is used to specify that the data of a data record read from the
controller or storage medium are to be written to or read from the tags you have configured
for the recipe.
The input or read data are transferred immediately to the controller: