Combination Devices
Input/output devices
4/4
Siemens ET G1 · 10/2008
Type Description
N 502 N 502 combination switch actuators
• Outputs identical or can be individually configured
• Operating mode can be adjusted for each output
(normal mode, timer mode)
• Switching behavior can be adjusted for each output
(NO contact/NC contact)
• Adjustable ON/OFF delay
• Selectable logic operation (AND/OR) of two communication
objects and adjustable start value of operation in the event of
bus power recovery
• Object can be added per output, night mode for limited ON
switching of lighting during the night
• Adjustable ON period during night or timer mode
• Selectable warning of impending OFF by turning the device
briefly on and off three times (flashing) during night or timer
mode
• Object for status indication can be added for each output
• Transmission of status objects on demand and/or automatically
after modification
• Integrated 8-bit scene control and integration of each channel
in up to 8 scenes
• Unchanged switching state of all outputs during power failure
• Switching state can be adjusted for each output after system
recovery
N 670 Universal N 670 I/O modules
2 x universal I/O, 2 inputs for Pt1000, 2 outputs 230 V AC, 10 A
• 2 universal inputs/outputs, each adjustable as
- Analog input 0 V ... 10 V DC
- Analog output 0 V ... 10 V DC
- Binary input for 10 V DC
- Binary output for 10 V DC
• Analog output with adjustable lower and upper limit of the
output voltage with adjustable voltage value in the event of bus
voltage failure and recovery
• Binary input with pulse edge evaluation
• Configurable actuated position (NO contact/NC contact)
• Positively driven operation
• Configurable behavior in the event of a bus power failure/recovery
• Analog input and PT1000 input with
• Limit value monitoring
• Limit value signal
• Adjustable limit values
• Adjustable hysteresis
N 605 N 605 thermal drive actuators
With 6 inputs and outputs each
• For control of electrothermal actuators for small valves for
heaters and cooling ceilings
• Configurable contact type (NO contact/NC contact)
• Configurable transmission of the input status objects by
request, in case of change, cyclically and/or in case of bus or
system voltage recovery
• Signaling of a short-circuited or overloaded output and
de-energizing of this output
• Configurable valve open and close time
• Configurable valve state (open or closed) in case of
de-energized output
• Adjustment to a non-linear valve characteristic curve
• With configurable control per output either by positioning
commands in percentage or by ON/OFF switch commands
• Conversion of percentage positioning commands into pulse
width modulated switch commands
• With per output configurable position in case of an open
window
• With transmission of an output status object on request or if the
switching state change
• Configurable behavior in the event of a bus power failure
• With optional calcification protection
• Configurable transmission
N 605/11 N 605/11 thermal drive actuators
6 inputs, 2 x 3 outputs for control of 2 heating/cooling mats
• For control of electrothermal actuators for small valves for
heaters and cooling ceilings
• Configurable contact type (NO contact/NC contact)
• 6 outputs, each with one silent semiconductor switch, divided
into 2 groups, each with 3 outputs and fixed assignment of
outputs to the forward flow and return valves
• Configurable valve open and close time
• Signaling of a short-circuited or overloaded output and
de-energizing of all outputs of the respective group
• Control of all outputs over ON/OFF switch command
• Transmission of the output status object on request or if the
switching state changes, optionally with automatic switchover
of the return valve between heating and cooling mode or with
switchover of the return valve over an object
• De-energizing of return valve output if the forward flow valves
are closed
• Configurable behavior in the event of a bus power failure
• Configurable transmission
N 526/02 N 526/02 switch/dimming actuators
triple, 230 V AC, 6 A, with constant light level control
• Integrated constant light level control per output (outputs are
master/slave-capable)
• Configurable starting value
• Adjustable dimming time
• Switching ON/OFF
• BRIGHTER/DARKER dimming
• Switching ON/OFF possible over BRIGHTER/DARKER dimming
• Set 8-bit value
• Night mode (lighting for cleaning)
• Send switching and dimming status
• Configurable behavior in the event of a bus power
failure/recovery
Accessories
AP 255
UP 255
AP 255, UP 255 indoor brightness sensors,
For N 526/02 switch/dimming actuators
• For direct connection to N 526/02 switch/dimming
actuators over a 3-wired cable of up to 100 m in length, which
also serves to power the sensor electronics
• Plug-in low-voltage terminal for connection of the cable to
N526/02
• Including two rigid optical fiber rods:
- Parallel light-sensitive surface for mounting surface
- Inclined (45°) light-sensitive surface for mounting surface
UP 255 indoor brightness sensors
• For mounting in a hollow-wall or flush-mounting box with
∅
58 mm and min. 40 mm mounting depth
• Cover made of white plastic (polystyrene)
• Dimensions (H x W x D): 30 x 52 x 33 mm
AP 255 indoor brightness sensors
• For ceiling or wall mounting
• Includes surface-mounting enclosure made of white plastic
(polypropylene) with
∅
70 mm and 24 mm in height
• Dimensions (H x W x D): 30 x 72 x 33 mm