Vista de página 113
Devices for Special Applications
Sun Protection, Anti-Glare Protection, Utilization of Daylight
Central weather/sun protection systems
6/8
Siemens ET G1 · 10/2008
6
Technical specifications
Type
AP 257/21 AP 257/31 AP 257/01 AP 257/11
Integrated sensors
• Heated wind sensors with no mechanical
components (0 … 70 m/s)
• Brightness sensors (0 … 99.000 lux)
• Dusk sensors (0 … 1000 lux)
• Outdoor temperature sensors (-40 … +80 °C)
• Heated precipitation monitors
Connection of up to
8 external sensors
1 wind sensor
(wind rotor monitoring)
• 7 analog sensors
Connection of up to
4 external sensors
• 1 wind sensor
(wind rotor monitoring)
• 3 analog sensors
Receivers for DCF77 signal
-- --
Transmission of all measured values over bus
Functions
Monitoring of all measured values up to
3 limit values
-- --
Sensor monitoring
-- --
Sunlight tracking control
-- -- --
Shadow edge tracking
-- -- --
Integrated shutter/blind control modules
-- --
• Controllable facades 8 4 -- --
AND operations
4 4 -- --
OR operations
4 4 -- --
8 OR operations for alarm/fault indications
-- --
Locking function for window cleaning tasks
Safety/alarm objects
Light/time function -- --
Enclosure data
Design AP AP AP AP
Degree of protection
IP44 IP44 IP54 IP54
Dimensions
•Height mm 69 69 160 160
•Width mm
67 67 250 250
•Depth mm
118 118 55 55
Display/control elements
LED for the display of DCF77 reception
-- --
Power supply
Electronics powered over an external power
supply unit
24 V DC
1)
24 V DC
1)
-- --
With electronics powered over an integrated
power supply unit. Supply voltage 230 V AC
-- --
Bus connection
Integrated bus coupling units
Bus connection via bus terminal
1)
External 4AC2 402 power supply unit.
For selection and ordering data, see page 6/9.
Type Description
Accessories for AP 257/21, AP 257/31 weather systems
Electronic power supply units
• For powering the AP 257/21 and AP 257/31 weather systems
with 24 V DC over the white/yellow core pair of the bus cable
• Max. cable length between power supply unit and weather
system: 100 m
• Rated operational voltage 85 ... 265 V AC (50/60 Hz),
85 ... 300 V DC
• Rated secondary voltage 24 V DC, +5 %
• Residual ripple < 100 mV
Rated secondary current 0.35 A
Electronic overload protection
Permissible ambient operating temperature: - 20 ... +60 °C
Degree of protection IP20
For mounting on EN 60715-TH35-7.5 mounting rail
Width: 2 MW (1 MW = 18 mm)
ET_G1_2009_en.book Seite 8 Freitag, 28. November 2008 9:50 09
© Siemens AG 2008
Vista de página 113