11 Alarms 11.90
11.9 General RESET alarms
Scan:
Effect:
Explanation:
Remedy:
2068
Pos. behind working area
During processing in AUTOMATIC/MDI
• NC START disabled
• Programmed travel not processed
Programmed end position of block is behind working area limitation in
one or more axes.
• Check working area limitation (positive and negative)
• Modify working area limitation by means of G25/G26
in program
Explanation:
2072
Incorrect input value (contour definition)
Value input not calculable for contour definition calculation.
Explanation:
2073
No intersection point (contour definition)
No intersection is obtained with programmed values when calculating
contour definition.
Explanation:
2074
Incorrect angle value (contour definition)
• Angle 360° programmed
• Angle value not practical for defined contour
Explanation:
2075
Incorrect radius value (contour definition)
• Radius too large
• Radius not permitted with defined contour
11–30 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02