09.91 11 Alarms
11.9 General RESET alarms
Effect:
Remedy:
2048
Circle end point error
• NC START disabled
• Programmed circle end point not on circle
• End point is further away by more than the input limit
in MD
• No geometry in first block of contour subroutine with L95 stock
removal cycle
Correct program
Explanation:
Remedy:
2056
Travel thru transf. center
• Radius axis (linear axis) tends to travel to the zero point of fictitious
coordinate system on the programmed path
• Change cutter radius
• Program different path motion
Significance:
Remedy:
2057
Opt. thread/rev. not available
• A thread has been programmed with G33, G34, G35 although this
function is not implemented in the control
• Feedrate per revolution G95 has been programmed
• Correct program
• Check MD
Explanation:
Remedy:
2058
3D option not available
• 3 axes programmed simultaneously
• Programmed block results in movement of 3 axes
• Correct program, check MD