DSB75 Development Support Board Rev. B1 Hardware Description
Strictly confidential / Released
s
DSB75_hd_v08 Page 75 of 94 29.09.2005
6 Connecting Antenna and GSM Module to DSB75
To prevent mechanical damage, be careful not to force, bend or twist the module. In order to
prevent short-circuits, ensure that the GSM module does not come into contact with any part
of the DSB75.
Follow these steps to connect the components:
Connect the supplied RF cable to the appropriate RF connector on the GSM module.
Plug the opposite end of the RF cable to the Hirose RF jack X505 located on the
component side of DSB75.
Connect the 80-pin B2B connector of the GSM module to the 80-pin board-to-board
connector X100 of the DSB75.
Insert the M2 screws (1) from the bottom side into the small holes of the DSB75 (5). Push
the self-gripping spacers (3) onto the screws as far as possible.
Mount the GSM module (4) upside down onto the M2 screws and spacers and secure it
with the M2 nuts (2).
Connect the external antenna to the SMA jack X506 of the DSB75.
Plug the power cables to the connectors X400 and X401 of the DSB75.
Figure 46: Mounting GSM module onto the DSB75
The pin assignment of the B2B connector can be found in Figure 4. Figure 47 shows a GSM
module directly connected to the DSB75.