Vista de página 24
Installing and connecting the device
3.3 Mounting the device
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
Operating Instructions, 04/2013, A5E03474888-02
25
Procedure
Note
Risk of guaranteed degree of protection not being met
If the mounting seal is damaged or protrudes beyond the device, the degree of protection is
not ensured.
Checking the placement of the mounting seal
To avoid leakage around the mounting cutout, do not install the mounting seal turned inside
out. If the mounting seal is damaged, order a replacement seal.
Note
Installing the device
Always mount the device according to the instructions in this manual.
Mounting clamps for ITC1200:
Mounting clamps for ITC1500, ITC1900, and
ITC2200:
Proceed as follows:
1. Working from the front, insert the device into the mounting cut-out.
2. Insert the mounting clamp into the cutout provided on the device.
3. Secure the mounting clamp by tightening the threaded pin.
Note
Observe a torque of 0.5 Nm when tightening the threaded pins of the mounting clamps:
4. Repeat steps 2 and 3 for all mounting clamps.
5. Check the fit of the mounting seal.
Result
The device is mounted and the degree of protection is ensured at the front.