Siemens SIMATIC NET PROFIBUS Manual de Serviço Página 68

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 238
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 67
Description of the DP Functions, Data, and Error Codes
DP Base Programming Interface for CP 5613/CP 5614
68
C79000-G8976-C108-01
4.1.1 Overview of the Functions
Administrative Functions
Name Purpose
DP_start_cp
Downloads the firmware and the database to the
CP 5613/CP 5614.
DP_open Logs on a DP user program, assigns a user handle.
DP_get_pointer Requests a pointer to the process image.
DP_init_sema_object This function initializes a semaphore at which your
user program can wait for the arrival of events.
DP_delete_sema_object This function clears a semaphore again.
DP_release_pointer Releases the pointer to the process image.
DP_close The DP user logs off.
DP_reset_cp Stops the CP firmware.
Standard DP Functions
Name Purpose
DP_set_mode
This function sets the required DP mode (OFFLINE,
STOP, CLEAR, OPERATE).
DP_slv_state This function activates or deactivates a slave
explicitly and can be used to change the
AUTOCLEAR property.
DP_read_slv_par
This function reads out the parameters of a DP slave
from the database.
DP_global_ctrl This function sends a global control command to one
or more slaves.
Vista de página 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 237 238

Comentários a estes Manuais

Sem comentários