Important OSM/ESM Functions
2-20
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
In problem-free operation, only the standby ports of the standby master are active
and handle data exchange. If the standby master or the link of one of the standby
ports of the master fails, all standby ports of the master are disabled and the
standby ports of the slave activated so that a functioning configuration is
re-established.
Note
Please remember that the same ports on the standby master and standby slave
must be configured as the standby ports. If an optical port of the OSM ITP62
(order number 6GK1105-2AA00)is used in an extended redundant coupling, it
must have at least hardware version 2.