Siemens OSM Manual do Utilizador Página 102

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 101
Web-Based Management (WBM)
4-41
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
4.10.3 FDB Unicast Configuration
Figure 4-25 FDB Unicast Configuration Window
In this window, you can enter or clear static unicast addresses in the FDB table.
Static addresses are not cleared by the address aging, see Section 2.5 and are
also retained when the OSM/ESM is turned off.
Entering Static Unicast Addresses
Follow the steps outlined below:
1. Select New Unicast Entry in the FDB Entry list box.
2. Enter the MAC address in the address box in hexadecimal (in each case 1
or 2 digits in one of the 6 fields).
3. In the Port list box, select the port to which packets with this (destination)
MAC address will be passed on.
4. Then click the Set New Values button.
Vista de página 101
1 2 ... 97 98 99 100 101 102 103 104 105 106 107 ... 157 158

Comentários a estes Manuais

Sem comentários