Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 40
If no data arrives:
• Check modules in HW Config.
• Address for inputs and outputs correctly applied in calling up the functional component?
(Hex/dec representation)
• If no block is used, is the I/O address within the process image?
Or get data with SFC 14/15.
• Heartbeat bit appears?
• Does only the first data block appear and no others?
Then the handshake does not work correctly? Check addresses.
Set handshake manually or with function block.
7.4 Resetting the CLV61x Dual Port to default setting
If the CLV61x Dual Port is connected to SOPAS ET, the device can be completely reset using the "Factory
Default" button:
Then carry out Permanent Storage via the "Green Diskette" symbol on the extreme right.
Following this, the PN name is empty and the CLV61x Dual Port can, if necessary, automatically get a new
name from the PLC.