Siemens CA 343 Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Fogões Siemens CA 343 Series. Siemens CA 343 Series User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Manual

SIMATIC S7 - OPEN MODBUS / TCP Communication via CP343-1 and CP443-1 Manual

Página 2 - SIMATIC S7

Getting started OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 2-12 Getting Started Procedure 1. Install

Página 3

Commissioning OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 3-13 Commissioning General Information The

Página 4 - Preface

Commissioning 3.2 Parameterization of the CP Parameterization of the CP If you have your stations connected with each other without a router, then t

Página 5

Commissioning Parameterization of the Communication Partner In the mode “CP is client” an “other station” is required for network configuration. After

Página 6 - Table of Contents

Commissioning 2) Properties – Other Station¾GeneralIn tab “General” you do not have to make any settings. 3.3 Network Configuration Communications C

Página 7

Commissioning After selecting Insert¾ New Connection... the dialog box ”Insert new connection“ will come up. Select the connection partner (Other St

Página 8 - 1 Product Description

Commissioning Object Properties of the Connection • An ID is provided. You can change the ID if needed. • Click on the button “Routing” and the confi

Página 9

Commissioning Unspecified Connection with “CP is server” If you have got a communication with CP as MODBUS server, the communication is set up as “uns

Página 10 - 2 Getting Started

Commissioning Click “OK“. This will take you back to the dialog box “Properties TCP connection“. The check box “active connection establishment” must

Página 11 - 3 Commissioning

Commissioning 3.4 How to Select the Appropriate Modbus Block General Information The block FC10 AG_CNTRL of the SIMATIC_NET library permits to termin

Página 12

SIMATIC S7 OPEN MODBUS / TCP Communication via CP343-1 and 443-1 Manual Edition 4.3 Preface, Table of Contents Product Description 1 Getting S

Página 13

Commissioning 3.5 Insertion of the Function Blocks into the Program Content of MODBUS library The following blocks are required for the Modbus commun

Página 14 - 3.3 Network Configuration

Commissioning OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 3-11Insertion of the Communication Blocks Th

Página 15

Commissioning OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 3-123.6 Multiple Connections via Port 502 G

Página 16

Commissioning OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 3-133.7 Start_up Characteristics of CP343 /

Página 17

Commissioning OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 3-143.8 Changeover of a Previous Version to

Página 18

Licensing 4 Licensing General The block MODBUSCP must be licensed for each CPU individually. The licensing takes place in two steps: reading the IDENT

Página 19

Licensing 3. The output IDENT_CODE shows an 18 character string Copy this string per copy/paste from the DB und and insert it in the form IT4Industr

Página 20

Licensing Declaration of the Registration Key REG_KEY The registration key REG_KEY must be declared for each call of the block MODBUSCP. The registr

Página 21

Licensing Missing or Wrong Licensing When the registration key is missing or a wrong one is detected, the SF LED (S7-300) or the INTF LED (S7-400) of

Página 22

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-15 Function Block MODBUSCP 5.1

Página 23

Safety Precautions and Warnings This manual contains warnings, which you should note for your own safety as well as for the prevention of dam

Página 24

Function Block MODBUSCP • Data transfer to and from the parameterized DB • Monitoring the data reception with a time-out • Verification of the regi

Página 25 - 4 Licensing

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-3Initiate Request CP is Client A

Página 26

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-45.2 Parameters of the Function

Página 27

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-5 Parameter Decl. Type Descript

Página 28

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-6 Parameter Decl. Type Descript

Página 29 - 5 Function Block MODBUSCP

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-7Parameter Decl. Type Descripti

Página 30

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-8id For each configured connecti

Página 31

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-9db_x The parameter db_x defines

Página 32

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-10DONE_NDR In the operating mod

Página 33

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-11DATA_TYPE The parameter DATA_T

Página 34

Preface OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 1Preface Purpose of the Manual The information i

Página 35

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-12WRITE_READ This parameter defi

Página 36

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-13Example: Parameterization of t

Página 37

Function Block MODBUSCP DB 14 + 0.0 640 +76.2 1250 + 0.1 641 + 0.0 1700 + 0.1 1701 +75.0 2300 +74.7 2299 DB

Página 38

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-155.4 Data and Standard Functio

Página 39

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-16MODBUSCP: SFCs for Miscellaneo

Página 40 - 5.3 Address Mapping

Function Block MODBUSCP OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 5-175.5 Renaming of Standard Func

Página 41

Diagnostics OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 6-16 Diagnostics Diagnostic Function The diagn

Página 42 - Modbus device

Diagnostics OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 6-26.2 Diagnostic Messages of the FB MODBUSCP

Página 43

Diagnostics OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 6-3Error messages FB MODBUSCP STATUS (Hex) Ev

Página 44

Diagnostics OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 6-4 Error messages the FB MODBUSCP STATUS (Hex

Página 45

Preface OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 2Additional Sources of Information All additiona

Página 46 - 6 Diagnostics

Diagnostics OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 6-5Error messages of FB MODBUSCP STATUS (Hex)

Página 47

Diagnostics OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 6-6Error messages of FB MODBUSCP STATUS (Hex)

Página 48

Diagnostics OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 6-7Error messages of FB MODBUSCP STATUS (Hex)

Página 49

Diagnostics OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 6-86.3 Diagnostic Messages of FC5/FC6 and FC5

Página 50

Application Sample OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 7-17 Application Samples General Inform

Página 51

Application Sample 7.1 Sample project STL General Information The sample project written in STL includes serveral Simatic stations for the different

Página 52

Application Sample 7.2 Sample project CFCGeneral Information The sample project written in CFC includes two Simatic S7-400 stations, one is parameter

Página 53

OPEN MODBUS / TCP communication via CP343-1 and 443-1 Appendix - 1 2XV9450-1MB00; Manual edition 4.3 A Literature MODBUS IDA MODBUS APPLICATION

Página 54 - 7 Application Samples

Customer Support Siemens AG Industry Sector I IS IN OC Werner-von-Siemens-Str. 60 91052 Erlangen Tel: ++49 9131 7-46111 Fax: ++49 9131 7-44757

Página 55 - 7.1 Sample project STL

Table of contents OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 iiTable of Contents 1... Product Des

Página 56 - 7.2 Sample project CFC

Table of contents OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 iii7.1... Sample project STL ...

Página 57 - A Literature

Product description OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 1-11 Product Description 1.1 Field of

Página 58 - Customer Support

Product description OPEN MODBUS / TCP communication via CP343-1 and 443-1 2XV9450-1MB00; Manual edition 4.3 1-21.2 Hardware and Software Prerequi

Comentários a estes Manuais

Sem comentários