XPS D Series - Certificate SIRA 01ATEX5262X
This equipment may be used in all hazardous dust zones with all conductive and
non-conductive dusts. The Type XPS-10D, XPS-15D, XPS-30D and XPS-40D Series
transducers have a maximum surface temperature of 135°C (275°F) (Temperature Class T4).
These units are certified for use in ambient range of -40 to 95°C (-40 to 203°F). The
transducers should not be used outside this temperature range. The XPS-10D, XPS-15D,
XPS-30D and XPS-40D Ultrasonic Transducers must be installed so the face of the
transducer is not substantially subjected to light.
Installation shall be carried out in accordance with the applicable code of practice, and by
suitably trained personnel.
These devices should only be supplied from a circuit containing a suitably rated fuse that has
a breaking capacity of 4000A. This fuse is included in Siemens Milltronics transceivers.
Repair of the equipment shall be carried out in accordance with the applicable code of practice
and Installation Instructions.
The certification of this equipment relies on the following materials used in their construction:
Enclosure Kynar complete with carbon nanotube (Polyvinylidene Flouride (PVDF) with carbon
nanotube [RTP Part No. 3399 X 93208 E]).
Encapsulant Stycast LA-9823-76 or Durapot 864 (as appropriate)
Manual override can be accomplished by using the disconnect switch provided in the building
installation of the associated controller.
XPS D Series Product Marking
SERIAL No.:
V 1.77 V r.m.s.; 250 V
I 44.2 mA r.m.s.
AMBIENTTEMP.: –40 C TO 95 C
IN
IN
:p
:
.
XPS-xxD
ULTRASONIC TRANSDUCER
EExmIIT4
0518
SIEMENS MILLTRONICS PROCESS INSTRUMENTS INC. PETERBOROUGH
SEE INSTRUCTION MANUAL FOR OPERATION.
PETERBOROUGH, CANADA
II 2G 1D T4
II 2GD T4
SIRA 01ATEX5262X