Communication
6.3 Acyclic Communication
Control Units CU240S
146 Operating Instructions, 10/2007, A5E00766042B AC
Field Data type Values Note
Unsigned8 0x02
0x03
0x04
0x05
0x06
0x07
0x08
Other values
0x40
0x41
0x42
0x43
0x44
Data type Integer 8
Data type Integer 16
Data type Integer 32
Data type Unsigned 8
Data type Unsigned 16
Data type Unsigned 32
Data type Floating Point
See PROFIdrive Profile
Zero (without values as a positive
subresponse to a write request)
Byte
Word
Double word
Error
Format
The format and number specify the adjoining space containing values in the
telegram.
Data types in conformity with PROFIdrive Profile shall be preferred for write
access. Bytes, words and double words are also possible as a substitute.
Unsigned8 0x00 … 0xEA No. 0 … 234
Limited by telegram length
No. of Values
Specifies the number of subsequent values.
Unsigned16 0x0000 … 0x0
0FF
Values
The values of the parameter for read or write access.
If the values make up an odd number of bytes, a zero byte is appended. This
ensures the integrity of the word structure of the telegram.