Introduction To ProfiBus DP
__________________________________________________________________
_______________________________________________________________________________________
Acromag, Inc. Tel:248-624-1541 Fax:248-624-9234 Email:sales@acromag.com http://www.acromag.com
16
ProfiBus DP Telegram Header Abbreviations and Frame Bytes
SD
1 byte Start Delimiter (used to distinguish telegram
format).
LE
1 byte Net Data Length (DU) + DA + SA + FC + DSAP +
SSAP.
LEr
1 byte Length
repeated.
DA
1 byte Destination Address– Where this message goes to.
SA
1 byte Source Address – Where this message came from.
The address of the sending station.
FC
1 byte Function Code (FC=Type/Priority of this message).
Used to identify the type of telegram, such as
request, acknowledgement, or response telegrams
(FC=13 signals diagnostic data). See below.
DSAP
1 byte Destination Service Access Point (COM port of
receiver). The destination station uses this to
determine which service is to be executed.
SSAP
1 byte Source Service Access Point (COM port of sender).
DU
1 to 32b
(or 1-244b)
Data Units/ Net Data from 1 to 244 bytes.
FCS
1 byte Frame Checking Sequence (ASIC addition of the
bytes within the specified length).
ED
1 byte End Delimiter (always 16H).
The following picture depicts the telegram sequence between a class 1
master and DP slave. The paragraphs that follow describe each telegram
frame byte in greater detail.
33Tbits
Idle Time
Sync
Time
SD2 LE
LE
LE
rep
SD2 DA
DA SA
FC DU
DU FCS
HEADER
ED
LE
rep
DP MASTER
SD2 SD2
HEADER
TRAILER
DP MASTER
SA FCS
FC ED
DP SLAVE
TRAILER
Immediate
Response
DP SLAVE
SRD Response, DU is Variable Length User Data
TELEGRAM CYCLE w/FRAME
SRD Request (Send & Request Data w/ Acknowledge)
DU is Variable Length User Data
INPUT DATA
REPONSE FRAME
TELEGRAM CYCLE
OUTPUT DATA
REQUEST FRAME
The Start Delimiter identifies the beginning of a telegram and its general
format. ProfiBus DP uses four types of Start Delimiters (SD) for request and
response telegrams, plus a fifth response for a short acknowledgement as
shown below. Note that the short acknowledge response does not use a
start delimiter. Also, a telegram response does not have to use the same
Start Delimiter as the request telegram.