For rack-integrated UPS units, OSM provides an orderly system shutdown in the event that a power
failure exceeds the powerfail-delay time interval specified for your rack-integrated UPS. To configure
this OSM power-fail support:
• For an HP Integrity NonStop NS16000 server, you must use the Configure Power Source as
UPS action for at least one processor switch power supply unit to tell OSM that a rack-integrated
UPS is configured to provide backup power.
• For an HP Integrity NonStop NS1000, NS1200, NS2000 series, NS2100, NS2200 series,
or NS14000 series server, you must use the Configure Power Source as UPS action for at
least one IOAM power supply or VIO power supply unit to tell OSM that a rack-integrated
UPS is configured to provide backup power.
• For an HP Integrity NonStop Blades System, you must use the Configure a Power Source as
UPS action for at least one power supply from the Enclosure object to tell OSM that a
rack-integrated UPS is configured to provide backup power.
Configuring OSM Power-Fail Support 47