Industrial Ethernet OSM/ESM
18
C79000-Z8976-C068-10
Properties of the ESM TP80
Electrical ports 8 x 10/100 Mbps autonegotiation ports
TP connectors (RJ-45 jacks)
Optical ports none
Maximum distance between two ESM
TP80 modules
100 m
Maximum ring span with 50 ESM TP80
modules
5 km
Digital Inputs 8 x DC 24V
Note
Industrial Ethernet OSM TP80 is available in two versions:
ESM TP80 with eight digital inputs:
The eight digital inputs are connected over two plug-in 6-pin terminal blocks on
the top of the device. To display the status of these inputs using the 8 device
LEDs, there is an additional display mode known as the "Input Status" that is
selected using a third mode LED.
ESM TP80 without digital inputs:
There are no digital inputs and the "Input Status" display mode is not available.
The operating states are displayed by 2 mode LEDs.