C79000-Z8976-C068-10
Properties of the OSM TP62
Electrical ports 6 x 10/100 Mbps
autonegotiation/autocrossover ports
TP connectors (RJ-45 jacks)
Optical ports 2 x 100 Mbps FO ports (full duplex)
BFOC sockets
Maximum distance between two ESMs 3000 m (multimode graded-index fiber)
Maximum ring span with 50 OSMs 150 km
Digital Inputs 8 x 24 V dc
Note
Industrial Ethernet OSM TP62 is available in two versions:
OSM TP62 with eight digital inputs:
The eight digital inputs are connected over two plug-in 6-pin terminal blocks on
the top of the device. To display the status of these inputs using the 8 device
LEDs, there is an additional display mode known as the "Input Status" that is
selected using a third mode LED.
OSM TP62 without digital inputs:
There are no digital inputs and the "Input Status" display mode is not available.
The operating states are displayed by 2 mode LEDs.