GAS CHROMATOGRAPHY
p
process
ADVANCE DATANET
HUB (DNH)
User’s Manual Edition 1/2007
Vista de página 0
1 2 3 4 5 6 ... 101 102

Resumo do Conteúdo

Página 1 - process

GAS CHROMATOGRAPHY p processADVANCE DATANET HUB (DNH) User’s Manual Edition 1/2007

Página 2

Safety Practices and Precautions, Continued Correct Operating Voltage Before switching on the power, check that the operating voltage listed on the e

Página 3 - Hub (DNH)

Siemens Energy & Automation, Inc. 7101 Hollister Road, Houston, TX 77040 Phone 713-939-7400, Fax 713-939-9050

Página 5 - Table of Contents

1/2007 Edition 2000585-001Siemens Energy & Automation, Inc.7101 Hollister Road, Houston, TX 77040United StatesPhone +1 (713) 939-7400Fax +1 (713

Página 6 - Table of Contents, Continued

Chapter 1 Introduction Overview Description The Advance DataNET Hub (DNH) functions as a communication router on an Advance Communications System (AC

Página 7 - Preface

Overview, Continued Package Configurations The Advance DataNET Hub (DNH) is available in three package configurations: • 19-inch Rack Unit (Figure

Página 8 - Technical Support

Overview, Continued DataNET Hub Hierarchy A network of DataNET hubs forms a tree-like hierarchy. A DNH may connect to as many as eight “down-stream

Página 9

DataNET Hub Operation DNH Links Figure 1-4 shows the individual links that connect three DataNET hubs and several end devices. The inter-hub links tra

Página 10

DataNET Hub Operation, Continued DataNET Switching DataNET switching operates by dynamically and automatically learning the topology of the network

Página 11 - Chapter 1

DataNET Hub Specifications Dimensions Rack Mounted Package Configuration See Figure 1-5 for Outline Drawing and Dimensions Wall-Mounted Package Con

Página 12 - Overview, Continued

DataNET Hub Specifications, Continued Ambient Installation Conditions Operation: -18° to +50°C (0° to 122°F) 0-99% relative humidity (non-condensing

Página 13

DataNET Hub Specifications, Continued DataNET Option, Standard Cable • Cable connection by Belden 9182 (single pair) or Belden SSD1743 (two pairs)

Página 14 - DataNET Hub Operation

DataNET Hub Specifications, Continued Communication Comparisons The Table below compares key communication features between using Advance Data Hiway

Página 16 - DataNET Hub Specifications

DataNET Hub Specifications, Continued Figure 1-5: Rack Mount Dimensions Dimension Table Figure 1-3 Description U.S. Inches Metric mm A Rack Hei

Página 17

DataNET Hub Specifications, Continued Figure 1-6: Wall Mount Dimensions Dimension Table Figure 1-4 Description U.S. Inches Metric mm A Wall Wid

Página 18

DataNET Hub Specifications, Continued Figure 1-7: Zone 1 – Wall Mount PKLMNOc/lSTTOPK0Pc/lRBOTTOMCQLEFTGHIJc/lQRIGHTDAEFFRONTB Dimension Table Fig

Página 19 - DataNET Cable

DataNET Hub Specifications, Continued Figure 1-7: Zone 1 – Wall Mount Dimension Table continued L Spacing from wall to front cable entry hole (to

Página 21

Chapter 2 Installation Overview Introduction This chapter is intended for installation personnel. After completing the procedures in this chapter the

Página 22

Unpacking and Inspection Description This section provides the steps to follow when receiving and unpacking the Advance DataNET Hub (DNH). Receipt of

Página 23

Wall or Rack Mounting Installation Instructions The Advance DataNET Hub should be: • Installed in a location that is free from shock and vibration.

Página 24

Wall or Rack Mounting Installation, Continued Rack Mounting The DNH rack mount configuration is designed for a standard 19-inch cabinet. The cabinet

Página 25 - Chapter 2

Site Wiring Requirements Description How you wire to the DNH is dependent upon the site requirements: • CE (Conformite European) Certified Areas •

Página 26 - Unpacking and Inspection

Advance DataNET Hub (DNH) Revised Printing – January 2007 User’s Manual 2000585-001

Página 27 - PROTECTION

Site Wiring Requirements, Continued DataNET Channels The DataNET channel connections can be either copper wire or fiber optic cable. The wiring metho

Página 28 - Wiring Requirements

Site Wiring Requirements, Continued Copper Wire Site Requirements The following information pertains when using copper wire. See Page 18, CE Install

Página 29 - Site Wiring Requirements

Site Wiring Requirements, Continued Use Cable Gland wiring method. Each cable gland allows entry of one duplex fiber cable. Cenelec Zone 1 or Zone 2

Página 30 - DataNET Channels

CE Installations Description This section should be used for installation sites that must conform to CE (Conformite European) Certification. Typicall

Página 31 - Cable Connections

CE Installations, Continued 3. A split ferrite filter must be clamped to DataNET copper wire and fixed immediately to the outside of the DNH; use pa

Página 32 - Communication Links

Wiring Connections Description Two removable access plates provide power and I/O entry through the underside of the DNH. The plates can be punched to

Página 33

AC Power (Mains) Connections DNH Power Supply Each of the DNH electronic modules has a Power Supply Assembly located below the DataNET Hub board. Each

Página 34 - CE Installations, Continued

AC Power (Mains) Connections, Continued Step Action 3. Install 15-Ampere circuit breaker, disconnect switches or receptacles in the incoming powe

Página 35 - ACCESS PLATES

AC Power (Mains) Connections, Continued Step Action 7. Plug the connector back into its base and secure the two recessed captive screws. 8. If

Página 36 - C INPUT CONNECTOR

DataNET Copper Connections Description The DNH consist of two identical hubs in one enclosure. The left side is usually the DataNET ‘A’ Hub and the

Página 37

Copyright Notice © 2002-2007 by Siemens All rights reserved. This publication is for information only. The contents are subject to change without noti

Página 38

DataNET Copper Connections, Continued DataNET Ports See Figure 2-1. Each DataNET Hub board has nine DataNET ports. One of the DataNET ports is dedica

Página 39 - ‘B’ HUB

DataNET Copper Connections, Continued Cable Impedance Settings Behind each single port connector is an associated jumper pin block, see Figure 2-1.

Página 40 - CONNECTORS

DataNET Copper Connections, Continued Down Link Wiring with DataNET Hub Signal Equalizer Board Step Action 1. Plug the DataNET Hub Signal Equali

Página 41

DataNET Copper Connections, Continued Each of the four-downlink connectors (TB15, TB16, TB17, TB18) contains wring terminals for two downlink ports;

Página 42

DataNET Hub Signal Equalizer Board Description This section sets the switches on the DataNET Hub Signal Equalizer board. This board is used to equali

Página 43 - TB15 – TB18

DataNET Hub Signal Equalizer Board, Continued Switch Setting for Unknown Cable Lengths When cable lengths are unknown, or the cable is other than th

Página 44 - Recommended Cable

DataNET Hub Signal Equalizer Board, Continued Table 2-2: Recommended Equalizer Board Settings Selec-tion Ratio DBloss SW1 SW2 SW3 1 2 3 1

Página 45

Signal Equalizer Settings for Non Recommended Cable or Unknown Cable Lengths Description This section is used to set the switches on the DataNET Sig

Página 46 - Sample Calculations

Signal Equalizer Settings for Non Recommended Cable or Unknown Cable Lengths, Continued View Measurements Signals are viewed with an oscilloscope. Sc

Página 47 - Cable Lengths

Signal Equalizer Settings for Non Recommended Cable or Unknown Cable Lengths, Continued Instructions & Examples This procedure is for determinin

Página 48

Table of Contents Preface iiiTechnical Support ivSafety Practices and Precautions v Chapter 1: Introduction 1Overview 1DataNET Hub Operations

Página 49

Signal Equalizer Settings for Non Recommended Cable or Unknown Cable Lengths, Continued Step Action 3. Examine the recorded signal levels and dete

Página 50

Signal Equalizer Settings for Non Recommended Cable or Unknown Cable Lengths, Continued Step Action 3. cont The next strongest signal is on port 6

Página 51

DataNET Fiber Optic Connections Description All DataNET Fiber Optic uplink and downlink port connections are made through the DataNET Fiber Optic Cou

Página 52

DataNET Fiber Optic Connections Fiber Optic Cable Type Duplex Fiber, 62.5/125 micron Port Connections 1. Plug the DataNET Fiber Optic Coupler boar

Página 53 - Port Connections

Ethernet Connections Description ETHERNET PORT The DNH consists of two identical hub modules in one enclosure. The left side is usually the DataNET ‘

Página 54 - Ethernet Connections

Ethernet Connections, Continued 10BASE-T Cable Requirements 1. The 10BASET data cable requires a minimum of two twisted pairs (transmit pair and a

Página 56

Chapter 3 Data Communications Setup Introduction Overview This chapter provides maintenance personnel instructions for making the operational setting

Página 57 - Chapter 3

Introduction, Continued Chapter Preview This chapter provides the following information: Topic Page Configuring Your PC 49Establishing a Connection

Página 58 - Introduction, Continued

Configuring Your PC Description The Advance DataNET Hub (DNH) has a built-in utility for configuring its operation. The Windows® HyperTerminal progra

Página 59 - Configuring Your PC

Table of Contents, Continued Command Summary 69Chapter 4: Command Descriptions 69 Parts Catalog 85Chapter 5: Introduction 85Available Parts 86 i

Página 60

Configuring Your PC, Continued 5. Click OK. The Connect To dialog box opens. 6. From the Connect using scroll list choose the Connect to COM 1 to co

Página 61

Configuring Your PC, Continued 8. Scroll each field and select the following Port Settings: Bits per second: 57600 Data Bits: 8 Parity: None Stop b

Página 62

Configuring Your PC, Continued 13. Click Terminal Settings button. The Terminal Settings dialog box will appear. 14. Ensure that the following defau

Página 63

Configuring Your PC, Continued 16. Click OK to return to main menu. 17. From the Main menu select File/Save As. The Save As dialog box will appear.

Página 64 - Establishing a Connection

Establishing a Connection Description Once your PC is set up, as described in Configuring Your PC, you are ready to connect to and configure the Advan

Página 65 - How to Log On

Establishing a Connection, Continued Password Format A password name can consist of any combination of alphanumeric characters. The alphanumeric nam

Página 66 - Remote Connection

Establishing a Connection, Continued 3. At the > prompt type: login password and press ↵ Enter. The Connect Screen will appear with the login info

Página 67 - Setting Network Address

Setting Network Address Description This section provides instructions to configure an Advance DataNET ‘A’ or ‘B’ Hub with its own Network Address.

Página 68

Setting Network Address, Continued See Assigning an IP Address, page 59 to learn how to assign an IP Address. Learning Hint 2. To configure the DNH

Página 69 - Assigning an IP Address

Assigning an IP Address Overview Each individual hub board (“hub-half”) in the system must have a unique IP address. This 32-bit number defines each

Página 70 - Firmware Updates

Preface Audience & Purpose This manual is intended to introduce users to the Advance DataNET Hub (DNH). It includes complete instructions for sa

Página 71 - Firmware Updates, Continued

Firmware Updates Description Periodically we will provide our users with firmware upgrades. Perform the following instructions to down load a new DNH

Página 72 - System Status LEDs

Firmware Updates, Continued 6. Click on Send Text File. The Send Text File dialog box will appear. In the Look in: window choose the directory on y

Página 73 - Hub Port LEDs

System Status LEDs Description The Advance DataNET Hub Communication boards have status LEDs for monitoring the DNH operation. Figure 3-1: Status LED

Página 74 - Cross Link Status

System Status LEDs, Continued Yellow (WARN) LED Blink Codes The yellow (WARN) blink codes are shown below. The yellow (WARN) status LED will light

Página 75 - Conflicts

System Status LEDs, Continued Ethernet Port LEDs There are four Ethernet Link Status LEDs. Link Active LED is Green (on) when a link is establishe

Página 76 - Troubleshooting, Continued

Troubleshooting Description This chapter is intended for maintenance personnel. Failure of the DNH to establish a link is the principle cause of most

Página 77

Troubleshooting, Continued The device may have an invalid or duplicate device ID, IP address, Subnet mask, or iproute. Configuration Parameter Errors

Página 78

Troubleshooting, Continued Signal Quality Problems If a DNH port green LED is off, or intermittently flashes between green and red the signal levels

Página 79 - Chapter 4

Troubleshooting, Continued 12. At the > prompt type: test off Test off places the selected port into a hardware diagnostic mode. 13. Disconnect t

Página 80

Chapter 4 Command Summary Command Descriptions Description This chapter is intended for maintenance personnel. This chapter provides definitions for

Página 81

Technical Support Contacts for Help Siemens provides support for the Maxum System worldwide. Contact information is provided on all Siemens products a

Página 82 - 72 • Command Summary

Command Descriptions, Continued list nnn, xxx List xxx events, starting with number nnn list on Continuously list events from the log buffer, as they

Página 83 - “display” Command

Command Descriptions, Continued “config address ip” command This command configures the hub-half IP address. Each individual hub board (“hub-half”)

Página 84 - “download”

Command Descriptions, Continued “config iproute” Command This command sets the address of the IP router to which the hub-half should send IP messages

Página 85 - “dn” Command

Command Descriptions, Continued “del” Command This command deletes selected items from the hub’s Source Address Table (SAT). The command offers opti

Página 86

Command Descriptions, Continued “display links” Command This command displays the hub-half’s link state table. The link state table indicates, for ea

Página 87

Command Descriptions, Continued 5. After you have selected the “hub_rom.mot” file and click on “OK,” HyperTerm will begin transmitting records to t

Página 88 - “list” Command

Command Descriptions, Continued dn window Displays the transmit “window” for the HDLC protocol used by DataNET. This is the number of I-frames that a

Página 89 - “login” Command

Command Descriptions, Continued dn portdelay time Sets the “port delay” parameter to the value given, in milliseconds. Actual times are rounded down

Página 90 - “port” Command

Command Description, Continued “help” Command This command generates a simple list of available commands. “list” Command Enter the list command at a

Página 91 - “timeout” Command

Command Description, Continued The event display gives a time-stamp, and an event description. All events other than frame-capture events are always

Página 92 - “trace” Command

Safety Practices and Precautions Safety First This product has been designed and tested in accordance with IEC Publication 1010-1, Safety Requiremen

Página 93 - “validation timeout”

Command Descriptions, Continued “logout” Command This command logs the user out of a session. The user must be logged out of the local device to logi

Página 94 - “verbose” Command

Command Descriptions, Continued “test” Command This command places a selected port into a hardware diagnostic mode. The command test 4 places port 4

Página 95 - Chapter 5

Command Descriptions, Continued “trace” Command The trace command controls the hub’s frame tracing function. This feature captures network messages s

Página 96 - Available Parts

Command Descriptions, Continued sets up tracing on downstream port 2, for input data only. trace crosslink output sets up tracing of frames sent on

Página 97 - Available Parts, Continued

Command Descriptions, Continued “verbose” Command This command controls the event buffer display’s “verbose” mode. When verbose mode is on, the list

Página 98

Chapter 5 Parts Catalog Introduction Overview This chapter is intended for maintenance personnel. The Chapter provides a list of replaceable parts an

Página 99

Available Parts Description The available DNH assemblies and parts, with their applicable part number are shown below. Part Description Ordering Numb

Página 100

Available Parts, Continued Part Description Ordering Number Cable, fiber optic patch, 3 meter, MM 62.5/125; 2 fiber 127002-008 Cable, 4 pair, UTP,

Comentários a estes Manuais

Sem comentários