G3 Electronics
00497GB-2009/R01
Availability, design and specifi cations are subject to change without notice. All rights reserved.
X024 - 12
www.asconumatics.eu
PROFIBUS DP
PROFIBUS DP is a vendor-independent, open
fieldbus protocol designed for communication
between automation control systems and distributed
I/O at the device level.
Numatics’ G3 PROFIBUS DP nodes have an
integrated graphic display and are capable of
addressing combinations of up to 544 Inputs /
Outputs.
The G3 PROFIBUS DP nodes have been designed
and tested to conform to the PROFIBUS standard
EN50170. Certification has been done by the
PROFIBUS Interface Center (PIC) according to the
guidelines determined by the PROFIBUS Trade
Organization (PTO). The certification process
ensures interoperability for all PROFIBUS devices.
More information regarding PROFIBUS can be
obtained from the following WEB site:
www.profibus.com
Technical Data
ELECTRICAL DATA VOLTAGE CURRENT
Node Power at Max. Brightness 24 VDC +/- 10% 94 mA
Valves & Discrete I/O 24 VDC +/- 10% 8 A maximum
Power Connector Single key 5 pin 7/8” MINI type (male)
Communication Connector Single reverse key (B-Coded) 5 pin M12 type (1 male and 1 female)
LED's Module Status and Network Status
OPERATING DATA
Temperature Range (ambient) -23º to +50º C
Humidity 95% relative humidity, non-condensing
Vibration / Shock IEC 60068-2-27, IEC60068-2-6
Moisture Protection IP65, IP67 (with appropriate assembly and termination)
CONFIGURATION DATA
Graphic Display Display used for setting Node Address, Baud Rate, Fault / Idle Actions, and all other system settings.
MCM (Manual Confi guration Module) Optional module containing DIP switches for setting node address and baud rate.
ARM (Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of total or partial system failure
Maximum Valve-Solenoid Outputs 32
Maximum Addressable I/O Points Various combinations of 544 inputs / outputs (1200 bits)
NETWORK DATA
Supported Baud Rates Auto-Baud from 9.6k to 12M Baud
Bus Connector Single reverse key (B-Coded) 5 pin M12 type (1 male and 1 female)
Diagnostics Power, short, open load conditions and module health are monitored
Special Features Supports Class 2 PROFIBUS-DP master with auto-confi guration and fail-safe device settings
WEIGHT
PROFIBUS-DP
Communication Module
227g
DESCRIPTION
REPLACEMENT
PART NUMBER
PROFIBUS DP
communications module
(node)
240-239
PROFIBUS DP
communications module
(node)
Automotive industry
240-301
Profibus DP
COMM
MALE FEMALE
Pin 1 = +5 VDC
Pin 2 = Data Line A
Pin 3 = Common 0 VDC
Pin 4 = Data Line B
Pin 5 = Earth Ground
POWER
MALE
Pin 1 = 0 VDC (valves & outputs)
Pin 2 = 0 VDC (node & inputs)
Pin 3 = Earth Ground
Pin 4 = +24 VDC (node & inputs)
Pin 5 = +24VDC (valves & outputs)
Comentários a estes Manuais