Siemens EK 746 Series Instruções de Operação Página 20

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 90
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 19
Mounting
5.1 Removing / fitting the housing cover
SCALANCE W786 outdoor access point
20 Operating Instructions, 06/2013, A5E02280428-08
Figure 5-1 Removing the cover
A Sealing cap
B Cover screw
C Housing cover
Follow the steps below to remove the housing cover:
1. Remove the sealing caps from the housing cover (position
A
in the figure above)
2. Loosen the screws in the cover (position
B
in the figure above).
3. Remove the housing cover (position
C
in the figure above).
Fitting the housing cover
Fitting the housing cover is carried out in the reverse order. Tightening torque for the cover
screws 1.8 Nm.
Vista de página 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 89 90

Comentários a estes Manuais

Sem comentários