Configuring alarm inputs
78
Siemens Building Technologies
Fire Safety & Security Products 03.2009
Tip: By clicking and dragging on the click points 2 or 3 you can conveniently select
or deselect multiple columns or time segments.
Exporting a time control file
The Export button can be used to back up the time control file and transfer it to
other systems.
1. Click the Export button
.
Î The Save As... dialog will open.
2. Select the directory into which you would like to export the time control file.
3. Enter a name in the File name field.
4. Click Save.
Î The time control file will be exported.
Importing time control
You can import a saved time control file with the Import button.
NOTE:
If the time control has already been configured, this configuration will be replaced.
1. Click the Import button .
Î The Open dialog will open.
2. Select the time control file to import.
3. Click Open.
Î The time control file will be imported.
11.2.4 Testing the configuration of an alarm input
Fig. 69 The signal detected LED icon on the Alarm input tab
Prerequisites
See Section
1094H5.1, page 1095H17.
z The SISTORE MX NVS software is in configuration mode.
See
374HSection "1096HOpening configuration mode", page 1097H18.
1. Select the Alarm input tab.
2. Select the alarm input you want to test from the list (
375Hsee 1098HFig. 631099H, page 1100H74).
3. Trigger the (physical) alarm input.
Î The LED icon will appear bright green briefly if the signal of the alarm input
was detected.